In order to modify other settings press the SET push-button twice. This will cause numbers to appear on the display,
while the red hyphen will remain next to the word VACUUM.
VACUUM mode makes it possible to vary the time of air suction inside the chamber from 1 to 60 seconds. To modify
these settings press the + and – push-buttons (n°4 pg.12).
Press the SET push-button again twice. The red hyphen will position itself next to the word SEAL, this will make it
possible to modify the time for sealing the sachet from 0 to 10 seconds, by pressing the + and – push-buttons (n°4
pg.12).
In order to modify the last setting press the SET push-button again twice, the red hyphen will position itself next to
the word GAS. With the help of the + and – push-buttons (n°4 pg.12) it is possible to modify the time of aggregate
gas delivery from 1 to 30 seconds.
Insert the sachet inside the decompression chamber in such a way that the mouth of the bag rests on the sealing
bar.
In the case of aggregate gas delivery cycles insert the nozzles near the sealing bar, inside the mouth of the sachet.
Do this in such a way that the product contained inside the sachet is nowhere near the sealing bar.
Lower the chamber cover and press it downwards. The machine will start automatically at the lowering of the cover.
Maintain pressure with your hand on the cover until the vacuum inside the decompression chamber is such that it
independently holds the cover downwards.
At the end of the working cycle the machine will automatically come to a stop and the chamber cover will lift-up.
Check that the seal does not create vaccum loss and, that the sachet does not have holes or tears.
Use of the vacuum packing machine with sealing bar for external
vacuum within jars or containers MSD300P-300-400-500
The vacuum packing machine, by way of a tube adapter (optional), is able to suction air even within jars and/or
containers.
Thanks to the valves on the lids of these particular containers (caps on jars and containers with covers furnished by the
manufacturer are optional) the machine is able to suction the air inside of them.
Automatic operation MSD300P-300-400-500
Press the push-button with the
that the "Welcome" message appears on the display.
If you wish to modify the working language press the SET push-
button (n°2 pg.11) while viewing the "Welcome" message. Select,
then, the desired language by pressing the + and – push-buttons
(n°3 pg.11).
After the "Welcome" message disappears press the SET push-
button (n°2 pg.11) and wait until the word "Temperature" appears
on the display, proceed then to set the level at 0 using the + and –
push-buttons (n°3 pg.11). Press the SET push-button again to
memorize the new "Temperature" level.
Using the MODE push-button (n°4 pg.11) select the "Vacuum
Only" mode.
Insert the tube adapter in the connecting nozzle present inside the
decompression chamber.
The machine will start automatically at the lowering of the
movable bar or by pressing the SEAL/PUMP push-button (n°5
pg.11).
Wait until the suction level reaches the number 8. Shut off, then,
the machine pressing the SEAL/PUMP push-button (n°5 pg.11).
symbol (n°1 pag.11) and verify
USE AND CLEANING
INFORMATION