Checking Charging Parameters - MicroPower Sharp 50 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
selected charging curve. Blue light is flashing
with 2 Hz constantly.
6. For each press of the STOP button, the charger
moves down one step in the table to the next
code. After the last code it returns to code 1.
7. Once the lights show the required charging
curve, press and hold the STOP button again
for 3 seconds.
The charger will respond by flashing three
times with all the lights and then display the
selected battery nominal voltage code. Blue
and green lights are flashing with 2 Hz
constantly.
8. For each press of the STOP button, the charger
moves down one step in the table to the next
code. After the last code it returns to code 1.
9. Once the lights show the required cell count,
press and hold the STOP button again for 3
seconds.
The charger will respond by flashing four times
with all the lights and then all lights turn off.
10. In order to return to normal function, shortly
disconnect the mains power to the charger.

Checking charging parameters

1. Disconnect the mains power to the charger and
disconnect the battery.
6
2. Connect the charger to the mains power.
3. Within 30 seconds of connecting the mains
power, press and hold the STOP button for 3
seconds.
The charger will respond with one flash from all
the lights and then display the selected
capacity code.
4. Hold the STOP button again for 3 seconds.
The charger will respond by flashing two times
with all the lights and then display the
selected charging curve. Blue light is flashing
with 2 Hz constantly.
5. Hold the STOP button again for 3 seconds.
The charger will respond by flashing three
times with all the lights and then display the
selected battery nominal voltage code. Blue
and green lights are flashing with 2 Hz
constantly.
6. Hold the STOP button again for 3 seconds.
The charger will respond by flashing four times
with all the lights and then all lights turn off.
7. In order to return to normal function, shortly
disconnect the mains power to the charger.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sharp 100

Tabla de contenido