SPECIFICATIONS

Model
TSM 8 DUO - outdoor
Air conditioner type
Multi split DC Inverter
Cooling capacity*
W
5200 (1230 - 5860)
EE rating cooling*
SEER*
Heating capacity*
W
5860 (1290 - 6280)
EE rating heating*
SCOP*
Dehumidifying capacity ** / ***
l / 24 h
Power consumption cooling
kW
Power consumption heating
kW
Yearly power consumption cooling / heating
kWh
298 / 1637
Power input
V / Hz / Ph
220-240 / 50 / 1
Current (nom.) cooling / heating
A
Max. current
A
Air flow **
m3/h
For rooms from - to **
m3
Suited for regions W / A / C
W / A / C
Fan speeds
Compressor type
Thermostatic range
°C
Operating range
Manual / mechanical / electronic control
Remote control Yes / No
Air filter type(s)
Refrigerant type / filling
C / g
R410A / 1800
Refrigerant GWP
CO2 equivalent
Diameter refrigerant piping Fluid - Gas
mm
1/4" / 3/8"
Normal suction / discharge pressure (max)
bar
8.5 / 30.5 (12 / 41)
Dimensions indoor unit (WxHxD)
mm
Dimensions outdoor unit (WxHxD)
mm
780x605x290
Net weight indoor unit
kg
Net weight outdoor unit
kg
Gross weight indoor unit
kg
Gross weight outdoor unit
kg
Sound level indoor unit****
dB(A)
Sound level outdoor unit****
dB(A)
Sound pressure level indoor unit (low)****
dB
Protection indoor unit
IP
Protection outdoor unit
IP
Allowable power fuse
AC 250V / 3.15A
*
EN 14511/EN 14825
**
Use indicative
***
Remove moisture at 27°C, 60% RL
**** EN 12108
4
54
TSM 832 DUO -
TSM 8 MULTI - outdoor TSM 825 DUO - indoor
Multi split DC Inverter
Multi split DC Inverter
Multi split DC Inverter
6150 (2800 - 6600)
2600 (1000 - 3100)
3500 (1050 - 3700)
A++
A++
A++
6.1
6.1
6.1
6600 (2450 - 6900)
2600 (1000 - 3800)
3500 (1050 - 4500)
A+
A+
A+
4.0
4.0
4.0
24
1.5
1.88
0.04
1.49
1.71
0.04
352 / 2098
149 / 910
200 / 1225
220-240 / 50 / 1
220-240~ / 50 / 1
220-240~ / 50 / 1
6.8 / 6.7
8.5 / 7.8
0.2 / 0.2
0.2 / 0.2
8.4
11
650
140 - 185
200 - 270
60 - 85
80 - 100
W / A / C
W / A / C
W / A / C
3
Rotary
Rotary
Rotary
16 - 31
16 - 31
-15 - 53
-15 - 68
Electronic remote
Electronic remote
control
Yes
Mesh
R410A / 2300
2088
2088
3.759
4.803
1/4" / 3/8"
1/4" / 3/8"
1/4" / 3/8"
8.5 / 30.5 (12 / 41)
11.5 / 19 (28.5 / 45)
11.5 / 19 (28.5 / 45)
811x292x205
811x292x205
902x650x307
8.5
40
50
10.5
44
55
40
55
58
-
IPX0
IPX4
IPX4
AC 250V / 3.15A
AC 250V / 3.15A
AC 250V / 3.15A
indoor
A++
6.1
dispose them according the legislation applicable. They are harmful to the environment.
A+
4.0
28.8
Environmental info: This device contains fluorinated greenhouse gases, as stated in the Kyoto protocol. The
0.04
equipment may be repaired or dismantled only by professional, trained personal.
0.04
This device contains refrigerant R410A, the amount is indicated in the table above. Don't let R410A escape
into the atmosphere: R410A is a fluorinated greenhouse gas with greenhouse gas effect (GWP) = 1975.
680
Internet:
In order to provide a better service, you can download the latest version of the user, installation, or service
3
manual at www.qlima.com.
Rotary
control
Yes
Mesh
9.0
11
40
-
IPX0
Don't dispose electrical devices with household waste; deliver it to a designated collection
point. Contact the local authorities for information about places for disposal of electrical
devices. When electrical devices are dumped at landfills or dumps, hazardous substances can
leak into the groundwater and get into the food chain, with all consequences for the health
of the local population. When replacing old devices it is the legal responsibility of the supplier
to collect the old device for disposal. Don't throw batteries into fire. They can explode or leak