M07 - COMMUNICATION
P07.n.01 Serial node address
P07.n.02 Serial speed
P07.n.03 Data format
P07.n.04 Stop bits
P07.n.05 Protocol
P07.n.06 IP Address
P07.n.07 Subnet mask
P07.n.08 IP port
P07.n.10 Client / server
P07.n.11 Remote IP address
P07.n.12 Remote IP port
P07.n.13 IP gateway address
M08 - LIMIT TRESHOLDS
P08.n.01 Reference measurement
P08.n.02 Function
P08.n.03 Upper threshold
P08.n.04 Multiplier
P08.n.05 Delay
P08.n.06 Lower threshold
P08.n.07 Multiplier
P08.n.08 Delay
P08.n.09 Normal status
P08.n.10 Latch
P07.n.01 = Serial address (node number) for the communication protocol.
P07.n.02 = Serial communication speed.
P07.n.03 = Data format. Can be set to 7 bits for ASCII protocol only.
P07.n.04 = Number of stop bits.
P07.n.05 = Communication protocol selection.
P07.n.06, P07.n.07, P07.n.08 = TCP-IP coordinates for application with Ethernet interface. Not used for other types of interface modules.
P07.n.10 = Enabling TCP-IP connection. Server - Awaits connection from a remote client. Client - Establishes a connection to the remote server.
P07.n.11, P07.n.12, P07.n.13 = Coordinates for the connection to the remote server when P07.n.10 is set to Client.
Note: This menu is divided into 4 sections, for limit thresholds LIM1...4.
P08.n.01 = Defines which multimeter measurement must be compared with limits.
P08.n.02 = Function of the limit threshold. It can be:
Max - LIMn active when the measurement is higher than P08.n.03. P08.n.06 is the reset threshold.
Min - LIMn active when the measurement is lower than P08.n.06. P08.n.03 is the reset threshold.
Min+Max - LIMn active when the measurement is higher than P08.n.03 or is lower than P08.n.06.
P08.n.03 and P08.n.04 = Used to define the upper threshold, that is made up by the value set in P08.n.03 multiplied by P08.n.04.
P08.n.05 = Trip delay on upper threshold.
P08.n.06, P08.n.07, P08.n.08 = As above, referred to lower threshold.
P08.n.09 = Allows to invert the status of the limit LIMn.
P08.n.10 = Defines if the threshold remains latched and thus needs to be reset manually (ON) or if it is automatically reset (OFF).
UdM
Default
Range
01
01-255
bps
9600
19200
38400
8 bit - n
8 bit, no parity
8bit, odd
8 bit, even
7 bit, odd
7 bit, even
1
Modbus RTU
Modbus RTU
Modbus ASCII
Modbus TCP
000.000.000.000
000.000.000.000 -
255.255.255.255
000.000.000.000
000.000.000.000 -
255.255.255.255
1001
0-9999
Server
Client / Server
000.000.000.000
000.000.000.000 –
255.255.255.255
1001
0-9999
000.000.000.000
000.000.000.000 –
255.255.255.255
UdM
Default
Range
OFF
OFF (measurements)
Max
Max - Min - Min+Max
0
-9999 - +9999
x1
/100 - x10k
s
0
0.0 - 600.0
0
-9999 - +9999
x1
/100 - x10k
s
0
0.0 - 600.0
OFF
OFF-ON
OFF
OFF-ON
1200
2400
4800
G
9600
B
1-2
11