M10 - COUNTERS
P10.n.01 Counter source
P10.n.02 Channel number (x)
P10.n.03 Multiplier
P10.n.04 Divider
P10.n.05 Counter description
P10.n.06 Unit of measure
P10.n.07 Reset source
P10.n.08 Channel number (x)
M11 - ENERGY PULSES
P11.n.01 Source measurement
P11.n.02 Count unit
P11.n.03 Pulse duration
M13 - INPUTS
P13.n.01 Input function
P13.n.02 Normal status
P13.n.03 ON delay
P13.n.04 OFF delay
M14 - OUTPUTS
P14.n.01 Output function
P14.n.02 Channel number (x)
P14.n.03 Idle status
M15 - USER-DEFINED PAGE
P15.01
Page enabling
P15.02
Title
P15.03
Measurement 1
P15.04
Measurement 2
12
Note: This menu is divided into 4 sections, for counters CNT1...4.
P10.n.01 = Signal that causes the increment of the counter (on rising edge). It can be the power-on of the multimeter (ON), the overcoming of a limit threshold
(LIMx), the activation of an external input (INPx).
P10.n.02 = Number of the channel (x) referred to previous parameter.
P10.n.03 = Multiplying factor. The pulse count is multiplied by this coefficient before being displayed.
P10.n.04 = Dividing factor. The pulse count is divided by this coefficient before being displayed. If different from 1, then the counter is displayed with 2 decimals.
P10.n.05 = Description of the counter. Free text 16 characters.
P10.n.06 = Unit of measure of the counter. Free text 6 characters.
P10.n.07 = Signal that causes the reset of the counter. As long as this signal is valid, the counter remains at value 0.
P10.n.08 = Number of the channel (x) referred to previous parameter.
Note: This menu is divided into 5 sections, for energy count pulses PUL1..5.
P11.n.01 = Type of energy to which the pulse is linked to.
P11.n.02 = Number of pulses for every kWh, kvarh or kVAh.
P11.n.03 = Pulse duration.
Note: This menu is divided into 4 sections, for digital inputs INP1...4.
P13.n.01 = Input function:
OFF – Input disabled
ON – Input enabled, used as a source for counters, etc.
LOCK – Settings lock. Does not allow access to both levels.
SYNC – Synchronisation for power/energy integration.
TAR-A, TAR-B – Energy tariff selection. See Energy tariffs chapter.
C01...C06, C08 – When this input is activated (edge-triggered), the correspondent command from the commands menu is executed.
P13.n.02 = Normal status of the input. Allows to invert the INPn activation logic.
P13.n.03, P13.n.04 = Delay on activation – deactivation of the input. Allow to filter the input status to avoid bouncing.
Note : This menu is divided into 4 sections, for digital outputs OUT1...4.
P14.n.01 = Function of the output:
OFF – Output disabled
ON – Output always enabled.
SEQ – Output enabled in case of wrong phase sequence.
LIMx – PULx – REMx – Output linked to the status of the programmed variable. Allows to connect the status of an output to the status of a limit
threshold, remote-controlled variable ,etc.
P14.n.02 = Number of the channel (x) referred to previous parameter.
P14.n.03 = Normal status of the output. Allows to invert the logic of the output function.
P15.01 = Enables user page.
P15.02 = Title of the user page. Free text, 16 characters.
P15.03, P15.04 = Measurements viewed in the two frames of the user page.
Default
OFF
OFF-ON-INPx-LIMx
1
1
1
CNTn
(Text – 16 chars)
Umn
(Text – 6 chars)
OFF
OFF-ON-INPx-LIMx
1
UdM
Default
kWh+
OFF, kWh+, kWh-,
kvarh+, kvarh-, kVAh
PUL / k
10
100 - 10 - 1 - 0.1
s
0.1
0.01-1.00
UdM
Default
TAR-A (n=1)
OFF - ON -
OFF (n=2...4)
LOCK - SYNC -
TAR A - TAR B -
C01 – C02 – C03 –
C04 – C05 – C06 –
OFF
s
0.05
0.00 - 600.00
s
0.05
0.00 - 600.00
UdM
Default
OFF
OFF-ON-SEQ-
LIMx-PULx-REMx
1
OFF
Default
OFF
OFF – ON
PAGn
(Text – 16 char)
OFF
OFF- (measurements)
OFF
OFF- (measurements)
Range
1-4
1-1000
G
1-1000
B
1-4
Range
Range
C08
OFF-ON
Range
1 - 8
OFF-ON
Range