Electrical Installation

All model ovens on the front cover are dual rated,
designed to be connected to either 208/240V AC,
60 Hz, 4 wire, single-phase power supply.
Circuit
Model
Required
MEDS301WS
20 AMP
PODS301W
ME301WS
MED301LWS
MED301RWS
MED301WS
30 AMP
POD301W
POD301LW
POD301RW
POD301W
ME302WS
PO302W
40 AMP
MEDS302WS
PODS302W
MED302WS
MED302LWS
MED302RWS
40 AMP
POD302W
POD302LW
POD302RW
MEDMC301WS
MEDMCW31WS-
MEM301WS
50 AMP 10200 40 AMP
PODMC301W
PODMCW31W
POM301W
The electrical supply should be a 4-wire single-phase AC.
Install a suitable conduit box (not furnished). An
appropriately-sized, UL-listed conduit connector must be
used to correctly attach the conduit to the junction box.
Note: Local Codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the bare ground wire from the oven to the white neutral
electrical supply wire.

Electrical Connection

The four-wire connection is preferred, but where local
codes permit, the three wire connection is also
acceptable.
WARNING
9
When connected to a 4 or 5-wire, 120/208-Volt 3-
phase power supply, the phase C conductor is not
required for the operation of the appliance.
8
Watts
Watts
Circuit
@
@
Required
240v
208v
4100
20 AMP
3500
6400
30 AMP
4800
9200
40 AMP
7000
9600
40 AMP
7500
8300

Four-wire Connection (Preferred)

Connect the red oven wire to the red electrical supply
wire (hot wire).
Connect the black oven wire to the black electrical
supply wire (hot wire).
Connect the white neutral oven wire to the white
neutral (not bare or green ground) electrical supply
wire.
Connect the green ground oven wire to the bare or
green ground electrical supply wire.

Three-wire Connection

Grounded Neutral
Connect red wire from oven to red wire in junction box.
Connect black wire from oven to black wire in junction
box.
Connect both green ground wire and white wire from
oven to white, green or bare neutral wire in junction
box.
The conduit cable, where connected at the oven, swivels.
Rotate conduit cable upward (or downward) and direct
through hole prepared in cabinet to attach to junction
box.
To maintain serviceability, the flex conduit must not be
shortened and should be routed to permit temporary
removal of the oven.