WaveInjector WI-400
Fig. 4.52:
Clamping surface of the coupling plate
1
1 – center of clamping surface
• Check the distance between the coupling plates WI Plate dist., see Fig. 4.53. The distance has to correspond to the
value displayed by the transmitter, see section 5.2.
• Fix the second coupling plate as described above.
Notice!
There must be no air pockets between the coupling plate and the pipe wall.
Fig. 4.53:
Distance between the coupling plates (installation with threaded rods, top view)
Negative distance between the coupling plates
When measuring in diagonal arrangement on pipes with a very small diameter, the distance between the coupling plates
WI Plate dist. can be negative, see Fig. 4.54.
It can be necessary to slide the coupling plate through the coupling plate aperture of the pipe mounting fixture of the oppo-
site transducer, see Fig. 4.55.
84
WI Plate dist.
Supplement to operating instruction - ENGLISH
2018-01-19, SUFLUXUS_WIV4-3EN