ADJUSTMENT OF THE OVEN
BURNER MINIMUM
This needs to be done only for the oven
burner by acting on the thermostat in the
following way:
– turn on the burner by setting the ther-
mostat knob on position max.
– remove the knob and unscrew the by-
pass screw (fig. 8.9) about three times
by passing a small flat screwdriver (Ø
3 mm blade, 100 mm length) through
the panel opening
– re-mount the knob and let the oven
heat up for about 10 minutes, then
bring the knob to position 1 (minimum)
to operate the thermostat by-pass
– after having removed the knob again
and being very careful not to turn the
tap rod, slowly screw the by-pass
screws "G" (fig. 8.9) until you obtain a
flame of 3-4 mm in height.
N.B. For G30/G31 the by-pass screw
must be fixed thoroughly.
G
Fig. 8.9
Flame correct
Flame faulty in
primary air
Flame with excess
primary air
IMPORTANT
All intervention regarding installa-
tion maintenance of the appliance
must be fulfilled with original facto-
ry parts.
The manufacturer declines any lia-
bility resulting from the non-com-
pliance of this obligation.
LUBRICATION OF THE GAS TAPS
– In case of difficulty in the gas taps
operation, call Service.
141