When operating in this mode, the tray need not be removed.
¤
Make sure the pump suction device (filter with a weight) is positioned inside the tray; otherwise the
condensates will not be pumped.
¤
Routinely clean the tray with a cloth to eliminate residues on the bottom that over timemight clog the
pump suction tube.
!
Never activate the pumping cycle without a drain tube; danger of flooding.
!
Before activating the pumping cycle by switch 10 (Fig. 7 ) make sure the drain tube is securely
connected to the tube holder 5 (Fig. 3 B); use the tube fastening band if necessary; pressure
caused by slope can cause the tube to detach and cause flooding.
!
Routinely check the suction filter of the pump to make sure it is clean; otherwise the flow rate
may become insufficient and create danger of flooding.
Fig. 5
EFT 400 BASIC control panel
Fig. 6
EFT 550 and 800 BASIC control panel
Fig. 7
EFT Plus control panel (all models)
GB 11
1 Main switch
2 Tray cutout
3 Voltage warning light
4 Tray full warning light
5 Analogical counter
1 Main switch
2 Tray cutout
3 Voltage warning light
4 Tray full warning light
5 Compressor warning light
6 ON cycle warning light
7 Hour counter display
1 Main switch
2 Tray cutout
3 Voltage warning light
4 Tray full warning light
5 Compressor warning light
6 ON cycle warning light
7 Hour counter display
8 Pump ON warning light
9 Hot defrost warning light
10 Pump switch