Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pres-
sures.
Do not allow the streams of the shower touch sen-
sitive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
Installation Instructions
•
The fitting must be installed, flushed and tested after
the valid norms.
•
The mesh washer must be insert to protect the over-
head shower against incoming dirt by pipework. Inco-
ming dirt leads to defects or/and can damage parts
of the shower; such caused faults voids all liability and
guarantee claims.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Connections G 1/2:
anti-pollution function
English
Symbol description
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
cold right - hot left
Assembly see page 31
Maintenance non return valve
(see page 36)
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
Maintenance Secuflex hose
(see page 36)
Repeat cleaning when pull out becomes
difficult.
Do not use silicone containing acetic acid!
Dimensions (see page 34)
Flow diagram
(see page 34)
Hand shower
Bath Spout
Spare parts (see page 38)
XXX = Colors
000 = chrome plated
090 = chrome plated/gold plated
Operation (see page 35)
Cleaning (see page 39)
and enclosed brochure