Electrical Connection - SCHOLTES TRP 741 OL Manual De Instrucciones

Encimera
Ocultar thumbs Ver también para TRP 741 OL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
Ventilation
To allow adequate ventilation and to avoid overheating of
the surrounding surfaces the hob should be positioned as
follows:
• At a minimum distance of 40 mm from the back
panel or any other vertical surfaces.
• So that a minimum distance of 20 mm is maintained
between the installation cavity and the cabinet
underneath.
Fixing
The appliance must be installed
supporting surface.
Any deformities caused by improper fixing could affect
the features and operation of the hob.
The thickness of the supporting surface
into account when choosing
the fixing hooks:
• 30 mm thick: 17,5 mm screws
• 40 mm thick: 7,5 mm screws
Fix the hob as follows:
1. Use short flat-bottomed screws to fix the 4 alignment
springs in the holes provided at the central point of
each side of the hob.
2. Place the hob in the cavity, make sure it is in a
central position and push down on the whole perimeter
until the hob is stuck to the supporting surface.
3. For hobs with raised sides: After inserting the hob
into its cavity, insert the 4 fixing hooks (each has its
own pin) into the lower edges of the hob, using the
long pointed screws to fix them in place, until the glass
is stuck to the supporting surface.
!
The screws for the alignment springs must remain
accessible.
!
In order to adhere to safety standards, the appliance
must not come into contact with electrical parts once it
has been installed.
All parts which ensure the safe operation of the
!
appliance must not be removable without the aid of a
tool.

Electrical connection

!
The electrical connection for the hob and for any built-
in oven must be carried out separately, both for safety
purposes and to make extracting the oven easier.
on a perfectly level
should be taken
the length of the screws for
Terminal board
On the lower part of the
appliance there is a connection
UNDERSIDE OF HOB
box for the different types of
electricity supply (the picture
is only an indication and is not
an exact representation of the
purchased model).
Single-phase connection
The hob is equipped with a pre-connected electricity
supply cable, which is designed for single-phase
connection. Connect the wires in accordance with the
instructions given in the following table and diagrams:
Voltage and
Electrical cable
mains frequency
230-240V 1+N ~
220-240V 1+N ~
50/60 Hz
Other types of connection
If the mains supply corresponds with one of the
following:
Voltage and mains frequency
• 400V - 2+N ~ 50/60 Hz
• 220-240V 3 ~ 50/60 Hz
• 230-240V 3 ~ 50/60 Hz
• 400V - 2+2N ~ 50/60 Hz
Separate the wires and connect them in accordance
with the instructions given in the following table and
diagrams:
Voltage and
Electrical cable
mains frequency
400V - 2+N ~
50/60 Hz
230-240V 3 ~
220-240V 3 ~
50/60 Hz
400V - 2+2N ~
50/60 Hz
If the mains supply corresponds with one of the
following:
Voltage and mains frequency
• 400V 3 - N ~ 50/60 Hz
proceed as follows:
!
The cable provided is not suitable for the following
types of installation.
GB
Wire connection
: yellow/green
N
: the two blue wires together
L
: brown and black together
Wire connection
: yellow/green;
N: the two blue wires
together
L1: black
L2: brown
: yellow/green;
N1: blue
N2: blue
L1: black
L2: brown
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Trp 642 dlTrp 632 td l

Tabla de contenido