He System Connection - Ferroli VARESE Serie Manual Técnico Y De Instalacion

Radiador de baja temperatura
Ocultar thumbs Ver también para VARESE Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Using a small rubber hammer, open the pre-drilled hole in
the cover enough to make the electro thermostatic valve
accessible.
Screw the thermostatic head and place the front. If the
model has the HE system, place the cover caps in the
front holes.
UNIT INSTALLATION
10.

HE SYSTEM CONNECTION

Models equipped with the HE system come pre-installed for the wa-
ter inlet sockets on the right-hand side. If your installation requires
inlet sockets on the left side, follow these points by order. Otherwise,
skip to point 4:
1. Before mounting the core on the wall remove the four screws that
support the fan HE KIT at the top.
2. Also remove the ambient sensor support by removing its two
screws .
3. Turn the heat exchanger around by 180º and position again the
HE KIT and the ambient sensor in the same position, as is shown
in figs.
4. Attach the clip of the water detection sensor to the tubes as is
shown in figs. 37 and 38, taking into account the position of the
water inlet sockets to the right or left .
DCHA
cod. A73022041
IZDA
EN
27

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

VareseVarese lpVarese heVarese lp he

Tabla de contenido