ELECTRICAL CONNECTION
Connect the appliance to the mains as shown (see Fig.4 –Fig.5):
1) Install, if not present, a cut-off switch (A) close to
the appliance with a magnetothermal trip and earth-
leakage contact breaker.
2) Open the doors (B), if present, and loosen the screws (C)
to disassemble the panel (D).
3) Connect the isolator switch (A) to the terminal board (H)
as shown in the figures and in the electrical diagrams at
the end of the manual. The chosen connection cable
must have features similar to the H07RN-F type with
an operating temperature of at least 80° C and have a
section suitable to the unit (see technical data in the
tables).
4) Pass the cable through the passage and tighten
the cable stopper, connect the conductors in their
corresponding position to the terminal board and fix
them. The yellow-green ground conductor must be
longer than the others so that, in the event that the
cable stopper breaks, it disconnects itself after the
voltage cables.
5) If the power cable is damaged, replace it with
a special H05RNF or H07RNF cable and have
the operation carried out by the manufacturer's
technical assistance or by a qualified person in
order to avoid any risks.
EQUIPOTENTIAL
The appliance must be connected to an equipotential
system. The connection terminal is positioned closed to
the supply cable input. It is marked by the symbol:
Connection to the water network
Connect the water pipe, if any, to the water supply
network by means of a mechanical filter and an on-off
valve. Before connecting the filter, let a certain amount of
MOD.
N°:
water flow to clean the pipes from any iron residue.
V
kW:
Hz: 50/60
IPX4
Water discharge
Connect the overflow discharge pipe to the wastewater
network. See technical drawings on page 6..
Attention!
The manufacturer is not responsible and will not
reimburse, under guarantee, damage resulting from
an improper installation and an installation that does
not conform with these instructions.
TESTING THE APPLIANCE
Important
Before putting into operation, test the equipment
to evaluate the operational conditions of each
component and single out any possible anomalies.
During this phase, it is important that conditions of
safety and hygiene are strictly followed.
Carry out the following controls to perform the test:
1) check that the main voltage is in conformity with the
appliance voltage
2) use the automatic isolator switch to check the electrical
connection
3) check the proper operation of safety devices
After testing, if necessary, train the users so that they
understand all the necessary skills to operate the
equipment in safe conditions, according to the regulations
in force in the country in which the equipment is to be
used.
INSTRUCTIONS FOR USE
ATTENTION !
Use the appliances under supervision and never let them
operate while empty.
Lights indicate if each unit is on or off.
The appliance does not need particular adjustment
interventions by specialized persons except for the
regulations made during the operation by the user.
Use only the accessories recommended by the
manufacturer.
During the initial uses of the appliance, an acrid or burning
smell may be detected. This will disappear after two or
three uses.
After use, the areas are hot for a certain amount of time
(residual heat). Do not rest your hands on them and be
sure to keep children away from them!
These are very important regulations, if they are neglected,
the appliance may not perform properly or the user may
be placed at risk.
This appliance cannot be used by people (including
children) with impaired skills or without experience and
knowledge unless under the supervision of a
person responsible for their safety who provides precise
instructions about the use of the unit.
Keep children under supervision to make sure that they
don't play with the unit.
THE ELECTRIC GRILLS INITIAL OPERATION
Initial Operation
Before using the unit for the first time, clean the tray
properly (see the paragraph "CARE OF THE APPLIANCE").
Check the appliance connection and put it into operation
according the instructions.
Switching on
Check that the draining tap on the control panel is
closed and be sure to use a suitable container to fill
the tank with water up to the overflow hole. Be sure
that the water does not reach the heating elements. If
there is a water filling tap, rotate the knob on the left
of the appliance's control panel counter-clockwise and
| 37