MIW-02 can be installed in any position
5)
Mounting can be made by screwing it directly on the panel through a M5 bolt.
5.1 RS-485 Connection
RS-485 must be connected directly point to point or in network with each parallel branch.
5.2 RS-485 Cares
1)
The cable shield must be grounded at all connections of the network through the RS-485
connectors
2)
All network equipment must be grounded;
3)
Lay the serial interface cables in separate conduits;
4)
Don't forget to install terminating resistors at the ends of the network and disconnect the
resistor from the internal network equipment.
4
Figure 5: MIW-02 - Installation mechanics
B A
RS-485
XC29
Terminal
Connection
Figure 6: Connection RS-485
;
Fastening M5
POW
SER
RS-485
RS-232
;
B A
Branch
Connection
RS-485
XC29