Ordering Codes; Technical Specifications - Johnson Controls RS-1100 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
English

Ordering Codes

Room Command Module
Ordering Codes
RS-1140-0000
---
RS-1150-0000
---
RS-1160-0000
---
RS-1160-0005
---
RS-1180-0000
Yes
RS-1180-0005
Yes
RS-1180-0002
Yes
RS-1180-0007
Yes
RS-1190-0000
---
RS-1190-0005
---
Accessories (order separately)
Ordering Codes
Description
Plastic Surface Mounting Kit
TM-1100-8931
Pointed tool for enclosure opening
TM-9100-8900

Technical Specifications

Products
Power Requirement
Power Consumption
Ambient Operating Conditions
Ambient Storage Conditions
Sensing Element
Output Signals
- Ambient Temperature
- Temperature Setpoint
- Temporary Occupancy Request
- Fan Speed Override
Output load
Sensing Element
Accuracy
Operation Status Indication
Terminations
Mounting
Enclosure Material
Colours
Protection Class
Dimension
(H x W x D)
Shipping Weight
Compliance
The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson
Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
This document is subject to change without notice
Interface to Occupant
---
---
---
Pushbutton
12...28 °C
Pushbutton
-...+
Pushbutton
12...28 °C
Integrated
-...+
Integrated
12...28 °C
Integrated
-...+
Integrated
12...28 °C
---
-...+
---
Models without Display
RS-1140-0000 / RS-1150-0000
RS-1160-000x / RS-1190-000x
15 VDC ± 5%
0.1 VA, no load
0 to 50 °C; 10 to 90% RH non condensing (and max. 30 °C dew point)
-40 to 70 °C; 5 to 95% RH non condensing (and max. 30 °C dew point)
0 to 10 VDC (linear in the range of 0 to 40 °C)
0 to 10 VDC, linear in the range of 0 to 40 °C(actual range 3 to 7 V)
Momentary contact switch (5 V at 1 mA)
---
3.5% from 0 to 10°C
1.2% from 10 to 30°C
3.5% from 30 to 40°C
Green LED for occupation mode indication
Terminal block with screw terminals in base for 1,5 mm² / 14 AWG (max.) wires
Direct surface mounting. Plastic base for surface mount with wiring conduits available on request (see "Ordering Codes")
Enclosure - Base - Occupancy Override Button: RAL9016 (GE86280)
---
RS-1140-0000 / RS-1150-0000: 80 mm x 80 mm x 32 mm
RS-1160-000x / RS-1190-000x: 80 mm x 80 mm x 35 mm
---
Yes
Yes
---
Yes
Yes
---
Yes
Yes
---
Yes
Yes
---
Yes
Yes
---
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
---
Yes
Yes
---
Yes
Yes
Pt1000 class A, EN 60751
min. 5 kΩ
Pt1000 class B, EN 60751
ABS+PC; self estinguishing HB UL 94
Setpoint Dial: RAL7047 (GE GY81118)
Enclosure: IP30 (EN 60529)
0,2 kg
CE Directive: 89/336 EEC EMCEN 61000-6-3, EN 61000-6-2
IS_RS-1100_24-85638-1222 Rev. D
Suitable Controllers
System 91
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Models with Display
RS-1180-000x
15 VDC ± 5%
1 VA, no load
0 to 10 VDC (linear in the range of 0 to 40 °C)
0 to 10 VDC, linear in the range of 0 to 40 °C(actual range 3 to 7 V)
Open Collector - 1 V @ 2 mA max.
(Auto-OFF-1-2-3): 0...10 VDC
max. 2 mA
±0.5°C
3-digit LCD display for temperature indication (resolution: 0.5 °C)
and 6 symbols for Fan Speed and symbol for sensor failure.
Backlight: White
RS-1180-000x: 80 mm x 80 mm x 35 mm
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rs-1140Rs-1150Rs-1160Rs-1180Rs-1190

Tabla de contenido