CONNECTING THE AMBIENT THERMOSTAT
AND/OR TIME CLOCK
(GREEN C.S.I. - GREEN R.S.I.)
HIGH VOLTAGE CONNECTIONS (fig. a, b, c)
The ambient thermostat and heating time clock contacts must be suitable for
V= 230 Volt.
Make the connections for the environmental thermostat and or the time clock on the
high voltage connections terminal board with 6 poles (M6) according to the following
charts, after having removed the Ubolt from the terminal board.
1= 2AF fuse
2= ambient thermostat
WATER TANK SENSOR CONNECTIONS (fig. d)
Make the connections for the water tank sensor to the terminal board M4 as indicated
in the diagram.
3= water tank sensor
LOW VOLTAGE CONNECTIONS (fig. e)
Make the connections for the low voltage functions to the 10-pole low voltage connections
terminal board (M10), as indicated in the diagram.
4= low temperature thermostat
5= external sensor
GREEN C.S.I.
GREEN R.S.I.
2
1
a
b
GREEN
C.S.I.
4
e
d
7
8
GREEN
R.S.I.
5
f
9
P2
10
CONEXIÓN TERMOSTATO AMBIENTE Y/O PRO-
(GREEN C.S.I. - GREEN R.S.I.)
CONEXIONES ALTA TENSIÓN (fig. a, b, c)
Los contactos del termostato ambiente y del programador horario tienen que
ser dimensionados para V= 230 Voltios.
Efectuar las conexiones del termostato ambiente y/o del programador horario en la
regleta de conexiones alta tensión de 6 polos (M6) según los esquemas, después
de haber quitado el puente presente en la regleta.
1= fusible 2AF
2= termostato ambiente
CONEXIÓN SONDA INTERACUMULADOR (fig. d)
Efectuar la conexión de la sonda interacumulador a la regleta M4 según el esquema.
3= sonda interacumulador
CONEXIONES BAJA TENSIÓN (fig. e)
Efectuare las conexiones de los aparatos de baja tensión a la regleta conexiones baja
tensión de 10 polos (M10) como indicado en figura.
4= termostato baja temperatura
5= sonda exterior
153
GREEN
C.S.I.
1
c
5
6
4
1
GRAMADOR HORARIO
2