W
HEN YOU THINK THAT TROUBLE HAS OCCURRED
In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the left operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An amplifi er may be required for the affected device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
S
PECIFICATIONS
Set name
Model
Indoor
Outdoor
Function
Power supply
Capacity
Input
Weight
Indoor
IP code
Indoor
LP ps
Permissible excessive
operating pressure
HP ps
Indoor (Super High/
Noise level (Single)
High/Med./Low/Silent)
Air fl ow volume
Indoor (Super High/
(Single)
High/Med./Low/Silent)
Indoor (Super High/
Noise level (Multi)
High/Med./Low/Silent)
Air fl ow volume
Indoor (Super High/
(Multi)
High/Med./Low/Silent)
Guaranteed operating range
Upper limit
Cooling
Lower limit
Upper limit
Heating
Lower limit
Model
sensible
Cooling Capacity
latent
Heating Capacity
Total electric power input
Sound power level
(per speed setting, if applicable)
(EU)2016/2281
—
MFZ-KT25VG
—
Cooling
Heating
kW
—
—
kW
0.020
0.024
kg
MPa
MPa
41/37/31/
44/37/30/
dB(A)
24/19
23/19
8.9/7.8/6.5/
9.7/7.3/5.6/
m
/ min
3
4.8/3.9
4.0/3.5
43/38/33/
44/39/34/
dB(A)
28/23
28/24
9.0/7.8/6.5/
9.7/7.8/6.3/
m
/ min
3
4.8/4.2
4.9/4.2
Indoor
Outdoor
32°C DB
23°C WB
21°C DB
15°C WB
*Note 2
27°C DB
—
20°C DB
—
DB: Dry Bulb
WB: Wet Bulb
MFZ-KT25VG
P
kW
1.98
rated,c
kW
P
0.52
rated,c
P
kW
2.90
rated,h
P
kW
0.024
elec
L
dB(A)
54/47/43/37/35
WA
—
MFZ-KT35VG
MFZ-KT50VG
—
Cooling
Heating
Cooling
~/N, 230 V, 50 Hz
—
—
—
0.020
0.024
0.037
14.5
IP20
—
4.15
41/37/31/
44/37/30/
48/42/37/
24/19
23/19
32/28
8.9/7.8/6.5/
9.7/7.3/5.6/
12.3/10.4/8.6/
4.8/3.9
4.0/3.5
6.7/5.6
43/38/33/
44/39/34/
48/42/37/
28/23
28/24
32/28
9.0/7.8/6.5/
9.7/7.8/6.3/
12.3/10.4/8.6/
4.8/4.2
4.9/4.2
6.7/5.6
Note:
1. Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB
Heating — Indoor:
20°C DB
Outdoor: 7°C DB, 6°C WB
2. As for specifi cations, please confi rm your dealer and/or refer to the
catalogue.
MFZ-KT35VG
2.45
1.05
4.00
0.024
54/47/43/37/35
—
—
MFZ-KT60VG
—
—
Heating
Cooling
Heating
—
—
—
0.052
0.063
0.059
15.0
49/44/40/
53/46/40/
51/47/41/
35/29
36/28
35/29
14.0/11.6/9.4/
15.0/12.3/9.6/
14.6/12.5/9.7/
7.7/6.0
8.0/5.6
7.7/6.0
49/44/40/
—
—
35/29
14.0/11.6/9.4/
—
—
7.7/6.0
MFZ-KT50VG
3.60
1.40
5.70
0.052
60/54/49/42/39
EN-7
EN