Multiplex MULTImate V 1.42 Manual De Instrucciones página 43

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

11. M
10 I
ENÜ
MPULSE MEAS
When the transmitter is switched on, this menu can be used to read out the pulse width at each receiver output
(channel), i.e. the signal which is otherwise used to control the components (servos, speed controllers etc.) connected
to the individual servo channels.
Connect the receiver output to be measured to the PC and Data port on one end of the MULTImate, using the data
lead supplied in the set.
Switch the receiver on (receiver must be connected to a receiver battery for power).
Action & Display
10 Impulse meas.
10-1 Impule len
1452 µs
12. M
11: MPX SENSORS
ENU
This menu is designed for configuring and setting up M-LINK sensors, and reading out the sensor values. The sensor
addresses for measured value and options can be assigned to specific lines on the transmitter's integral screen. Please
note that each address can only be assigned once, i.e. if there is an 'address clash' only one of the values is displayed.
This is explained here using as an example the configuration of the temperature sensor with its two measurement
channels. All M-LINK sensors are set up using the same method; the only difference is that not all of them have two
measurement channels.
• Connect the UNI lead (marked RX/S) attached to the M-LINK sensor to the PC and Data port at the end of the
MULTImate. Note that the sensor must not be connected to any other devices at this stage!
Action & display
11 MPX Sensors
11-1 Sens. value
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten (Gölshausen) • www.multiplex-rc.de
Operating Instructions - MULTImate – V1.42
.
10
Go back
...to main menu
11 Go back
...to main menu
11-1 Go back
to Sensors
11-1 Adress 0
no sensor
(...)
(...)
11-1 Adress 4
22.1°C
(...)
(...)
11-1 Adress 15
no sensor
Explanation
Main menu display "10 Impulse meas."
(Signal Measure)
Signal length display
The signal length is displayed on the screen of the
MULTImate, corresponding to the position of the
transmitter stick (switch, slider etc.)
Explanation
Main menu display "11 MPX sensors"
Displaying the values for the connected sensor
Measured values and set option values for the sensor
connected to the MULTImate can be displayed by
turning the rotary control on the unit.
This example shows the temperature of channel 1 of
the temperature sensor, with the default address 4.*
*
Factory default sensor addresses:
Addr 1:
U receiver voltage
Addr 2:
LQI downlink channel quality Receiver
Addr 3:
U1 voltage, channel 1
Addr 4:
T1 temperature, channel 1
Addr 5:
RPM (mag / opt)
Addr 6:
Altitude
Addr 7:
Climb rate
Addr 8
Addr 15 no default assignments!
Receiver
Voltage sensor
Temperature sensor
Rev-count sensor
Vario / altitude sensor
Vario / altitude sensor
Seite 20/22

Publicidad

Tabla de contenido
loading

Productos relacionados para Multiplex MULTImate V 1.42

Tabla de contenido