PARAMETS
CL.E.
13
de.a.
14
IN.D.
15
se.r.
16
se.f.
17
EL.T.
18
ST.P.
19
EN.C.
20
NE.P.
21
DE.F.
22
To set the default values: 1) access the advanced programming
function; 2) select the "dEf" parameter"; 3) activate the modification
mode ("0" on display"); 4) accept the modification (press "MENU"
and hold it down). A countdown should now appear: 49,48...,1 down
to "don". Release the key when finished.
To use both colours of a two-colour LED strip, make the connections
as explained in the CTLIGHT instructions and modify parameters
FP.r. as required (setting 2 or 3).
28
DESCRIPTION
Clearance. Allows to stop before the fully open position: it
is useful to avoid mechanical stress during opening.
Hold-to-run
0 = off
1 = on
0 = deactivated
1 = gate open light ON/OFF
2 = gate open light proportional
- Slow flashing with gate opening
- Quick flashing with gate closing
- Steady light if gate open
- 2 flashes + pause with gate stationary (position other than
closed)
3 = Electric lock
4 = Magnetic electric lock function with output active when
gate/door is closed
N.B. interface with an external relay with 24 Vdc winding. To
activate this function, the pre-flash must be enabled at the
recommended value of 1 sec (tP.r. ≠ 0)
5 = LED strip for gate open light (MODE 1)
- steady light when open and closed
- flashing light in all other positions
6 = LED strip for gate open light (MODE 2)
- gate closed steady red
- gate open LEDs off
flashing red in all other positions
Service interval cycle threshold.
(0 = off)
Enabling of continuous flashing indicating
service required with se.r. ≠ 0 (only active with gate
closed).
0 = off
1 = on
Electric lock activation time in seconds
High-speed motor start-up.
0 = on
1 = off
1 = Off (use of virtual encoder)
2 = On (use of motor's physical encoder)
1 to 10 pulses per revolution of the physical encoder
0 = Restore of factory settings for sliding gate motor
SC4224
1 = Restore of factory settings for sliding gate motor
SUN4224
2 = Restore of factory settings for sliding gate motor
SUN7224, SC7224
3 = Restore of factory settings for sliding gate motor
SUN11224, SC11224
4 = Factory setting restore for 4/6 mt barrier and up-and-
over door
5 = Factory setting restore for 8 mt barrier
DEFAULT MIN
0
0
0
10
0
4
0
1
4
0
To use just one colour of a LED strip, make the connections as ex-
plained in the CTLIGHT instructions and modify parameter IN.D. as
required (setting 5 or 6); parameter FP.r. cannot be set on 2 or 3.
* = The default value for barriers is 3
MAX
UNIT
TYPE
0
30
%
BA/OH
SL/BA/
0
1
OH
SL/BA/
0
6
OH
x 1000
SL/BA/
0
200
cycles
OH
SL/BA/
0
1
OH
SL/BA/
1
10
s
OH
SL/BA/
0
1
OH
SL/BA/
1
2
OH
SL/BA/
1
10
OH
SL/BA/
0
5
OH