Customising The System - Basic Menu - Key Automation CT102 24 Instrucciones Y Advertencias Para Su Instalación Y Uso

Central para un motor 24 vdc, para puerta de corredera, portón basculante o barreras
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
EN
CLEARING THE ENTIRE RECEIVER MEMORY
If you are in programming mode exit pressing the MENU button until -- appears. Press the DOWN (RADIO)
button for more than 2 seconds. Until the display shows the word "rad" (radio), then release the button
1. Press the DOWN (RADIO) button and hold it down until the LED lights up (about 3 seconds) and then goes
out (about 3 seconds).Release the key
2. About 1 second after the key is released, the KEY LED starts to flash
3. Press the key on the receiver as the LED flashes for the third time
4. If the deletion has been successful, the KEY LED will give one long flash
REMOTE MEMORISATION OF A REMOTE CONTROL WITH A REMOTE CONTROL ALREADY MEMORISED
A transmitter can be memorised without accessing the receiver. The user needs to have a transmitter memorised
previously, after which the procedure is as described below. The remote copy procedure must be carried out in
the area served by the receiver.
1. Press the key of the new remote control to be memorised, holding it down for at least 5 seconds
2. Press the key of the old remote control to be copied (if phase 1 has been successful, the automation system
will not respond)
3. Press the key of the new remote control to be memorised, holding it down for at least 3 seconds
4. Press the key of the old remote control to be copied, holding it down for at least 3 seconds, to confirm and quit
the programming mode
N.B If no commands are given for 7 seconds, the receiver automatically quits the programming mode

4.5 - Customising the system - BASIC MENU

If necessary, users may select a BASIC MENU which allows modi-
fication of the control unit's basic parameters. To select the BASIC
MENU proceed as described below.
Exampling of modifying a BASIC MENU parameter
UP
DOWN
MENU
Press the MENU key for 1 se-
cond to access the basic menu.
UP
DOWN
MENU
Press the MENU key for 1 se-
cond to display the parameter
in order to save the modified
value, or MENU quickly to quit
the function without saving.
24
UP
DOWN
MENU
After accessing the BASIC
MENU, press the + and – keys
to scroll through the functions.
UP
DOWN
MENU
Press the + and – keys to scroll
through the functions to modify
other parameters.
WARNING: to be certain of accessing the NORMAL OPERATION
display state, the starting point for accessing the BASIC MENU,
press the MENU key twice
UP
DOWN
MENU
To access the value modifica-
tion function, press the MENU
key for 1 second, until the va-
lue starts to flash quickly.
UP
DOWN
MENU
Press the MENU key quickly to
quit the menu.
(>3s)->
(>3s)->
(1s)+
(1s)+
3s
>5s
>3s
>3s
>3s
UP
DOWN
MENU
Press the + and – keys to to
modify the value.

Publicidad

Tabla de contenido
loading

Tabla de contenido