Descargar Imprimir esta página

Wieland SNT 4M63K Manual De Instrucciones página 5

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
Proper Use
The devices are safety switching devices. They must only be used as components of safety equipment on machines intended to protect
persons, material and plant.
Notes
The Performance Level (PL) and safety category in accordance with EN ISO 13849-1 depends on the external wiring, the application case, the choice of
control station and how this is physically arranged on the machine.
The user must carry out a risk assessment in accordance with ISO 14121-1.
The entire system/machine must undergo validation in accordance with the applicable standards on the basis of this.
In order for the specified Performance Level (PL) to be achieved, an average annual number of switching cycles must not be exceeded (see EN ISO
13849-1, C.2.4 and Tab. K.1), taking into account the prevailing device load (see EN ISO 13849-1, Tab. C.1) and the application case. Assuming that the
B
value for the maximum load is 400,000, this results in a maximum cycle number of 400,000 / 0.1 x 30 = 133,333 switching cycles/year.
10d
Operating the device not within the specifications may lead to malfunctions or the destruction of the device.
The supply input A1 also serves as a control input. This may lead to short disruptions or a lowering below the operating voltage in order to
switch to the release path.
The indicated times must be observed when the device is operated, otherwise the device could lock. Locking can be cancelled by opening the
safety inputs properly.
SNE expansion devices or external contactors with positively driven contacts can be used to duplicate the enabling current paths.
The device and the contacts must be protected at max. 6 A utilization category gG.
The devices are equipped with overload protection (for short-circuit). After the malfunction has been dealt with, the device is operational
again in approx. 3 s.
Control output S13 is exclusively for connecting control devices as defined in the operating instructions and not for connecting external
consumers such as lamps, relays or contactors.
Function diagrams
SNT 4M63K
Automatic start, synchro-check, equivalent
activation (installation 4)
SNT 4M63K
Manual start, equivalent activation
(installation 5)
t
= Min. ON time
M
t
/ t
= Operate time
A1
A2
t
= Synchronous monitoring time
S
t
= recovery time
W
t
= release time
R
SNT 4M63K
Automatic start, synchro-check, non-equivalent
activation (installation 1)
A1/A2
S14
S24
S35
K1
K2
13/14,
23/24,
33/34
SNT 4M63K
Manual start, non-equivalent activation
(installation 2)
A1/A2
S14
S24
S34
K1
K2
13/14,
23/24,
33/34
A1/A2
S14
S22
S35
K1
K2
13/14,
23/24,
33/34
A1/A2
S14
S22
S34
K1
K2
13/14,
23/24,
33/34
5

Publicidad

loading

Este manual también es adecuado para:

Snt 4m63k-a