Sorting Station
The MPS
may only be used:
For its intended purpose
When its safety functions are in perfect condition
Malfunctions which may impair safety must be eliminated immediately!

4.5 Working safely

General
Trainees should only work with the circuits under the supervision of an instructor.
Electrical devices (e.g. power supply units, compressors and hydraulic power units) may only be
operated in training rooms which are equipped with residual current devices (RCDs).
Observe the specifications included in the technical data for the individual components, and in
particular all safety instructions!
Malfunctions which may impair safety must not be generated in the training environment, and must be
eliminated immediately.
Wear personal safety equipment (safety glasses, safety shoes) when working on circuits.
Mechanical safety
Switch off the power supply!
Switch off working as well as control power before working on the circuit.
Only reach into the setup when it's at a complete standstill.
Observe possible overtravel of the drives.
Mount all of the components securely onto the slotted profile plate.
Make sure that limit switches are not actuated from the front.
Risk of injury during troubleshooting!
Use a tool to actuate the limit switches, for example a screwdriver.
Set all components up so that activation of switches and disconnectors is not made difficult.
Follow the instructions regarding positioning of the components.