8

Troubleshooting

Fault
Your cooler does not func-
tion (plug is inserted).
When operating from the
12 V socket (cigarette
lighter):
The ignition is on and the
cooler is not working.
No music.
Possible cause
Suggested remedy
There is no voltage
The ignition must be switched on in
present in the 12 V
most vehicles for voltage to flow at the
socket (cigarette
cigarette lighter.
lighter) in your vehicle.
No voltage present in
Try using another plug socket.
the AC voltage socket.
The inner fan or the
This can only be repaired by an author-
cooling element is
ised customer services unit.
defective.
The fitting of the 12 V
If the plug of your cooler becomes very
plug is dirty. This
warm in the 12 V socket fitting, either
results in a poor elec-
the fitting must be cleaned or the plug
trical contact.
has not been assembled correctly.
The fuse of the 12 V
Replace the fuse (5 A) in the 12 V plug
plug has blown.
(fig. 4 1, page 4).
The vehicle fuse has
Replace the vehicle's 12 V socket fuse
blown.
(usually 15 A). Please refer to the oper-
ating manual of your vehicle.
The batteries are
Insert three new 1.5 V batteries,
empty.
type AA (Mignon).