How To Correct Problems In The Machine - Clarke BOOST 28 Libro De Instrucciones

Ocultar thumbs Ver también para BOOST 28:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
There is no solution flow.
The solution flow does not stop.
The machine does not remove all the
water from the floor.
The batteries do not give the normal
running time.
Clarke
®
Operator's Manual (EN) - BOOST 28

HOW TO CORRECT PROBLEMS IN THE MACHINE

CAUSE
The solution tank is empty.
The solution valve is closed.
There is an obstruction in the solution hose
or filter.
The solution valve or electric wiring is
damaged.
The solution module is defective.
The solution valve is open.
The solution valve or wiring is damaged.
The solution valve is dirty
There is a damaged seat and washer in the
solution valve.
The solution module is defective.
The squeegee is up.
The squeegee tilt is not correct.
The recovery tank is full.
The screen filter is dirty.
There is an obstruction or damage in the
squeegee, squeegee hose or standpipe.
The vacuum motor is not running.
The squeegee hose is disconnected, or
damaged
The squeegee blade is damaged, worn, or
incorrectly installed.
The gaskets on the cover of the recovery
tank are damaged.
The battery terminals are dirty or damaged.
The electrolyte level is too low.
The batteries are not fully charged.
The charger is damaged.
The battery is defective.
The batteries are disconnected.
Brush is in heavy scrub setting.
ENGLISH
ACTION
Fill the solution tank.
Open the solution valve.
Remove the obstruction from the hose or filter.
Repair or replace the valve or the electric
wiring.
Replace solution module
Close or Clean the solution valve.
Repair or replace the valve and the wiring.
Clean the solution valve.
Replace the seat and washer.
Replace solution module.
Lower the squeegee.
To adjust See Figure 11, page 23.
Drain the recovery tank.
Clean the screen filter.
Remove the obstruction or repair the damage.
Check for tripped breaker. Have an authorized
service person make repairs.
Check and connect hose.
Turn or replace the squeegee blade.
Correctly install the squeegee blade.
Replace the gaskets.
Clean the terminals and connectors. Replace
the damaged cables. Charge the batteries.
Add distilled water to each cell and charge the
batteries.
Charge the batteries for a full 16 hour charge.
Have an authorized service person repair the
charger.
Check voltage of each cell while discharging.
Connect the batteries.
Adjust Pressure.
EN
- 25 -

Publicidad

Tabla de contenido
loading

Tabla de contenido