CONTROL WIRING DIAGRAMS
The CVW300 has two sealed connectors, XC9 and XC10, which are
used to wire control signals from the drive.
Figure 5: Identification of connectors XC9 and XC10
The functions of each terminal are listed in
and
Table 6 on page
9.
Table 5: Functions of terminals XC9
Terminal
XC9 - 01
A-HMI
XC9 - 02
B-HMI
XC9 - 03
+15 V
XC9 - 04
DGND
XC9 - 05
A
XC9 - 06
B
XC9 - 07
CANH
XC9 - 08
CANL
XC9 - 09
+15 V*
XC9 - 10
DI3
XC9 - 11
DI4
XC9 - 12
DI5
XC9 - 13
DI6
XC9 - 14
DI7
XC9 - 15
DI8
XC9 - 16
DO4
XC9 - 17
DO5
XC9 - 18
AO1
XC9 - 19
AO2
XC9 - 20
DGND
XC9 - 21
PTC+
XC9 - 22
PTC-
XC9 - 23
NC
(1) In order to use the CAN interface, contact WEG.
Table 6: Functions of terminals XC10
Terminal
XC10 - 01
+5 V_ENC
XC10 - 02
A
XC10 - 03
A
XC10 - 04
B
XC10 - 05
B
XC10 - 06
Z
XC10 - 07
Z
XC10 - 08
DGND
XC10 - 09
+15 V*
XC10 - 10
DO2
XC10 - 11
DO3
XC10 - 12
AI1
XC10 - 13
AI2
XC10 - 14
REF+
XC10 - 15
REF-
XC10 - 16
CONTACTOR
XC10 - 17
UDA
XC10 - 18
XCA
XC10 - 19
DI1
XC10 - 20
DI2
XC10 - 21
DO1 (NC)
XC10 - 22
DO1 (NO)
XC10 - 23
DO1 (COM)
Index
Variable Speed Drive for Electric Traction
Table 5 on page 9
Signal
HMI interface – RS-485
HMI power supply
HMI reference
RS-485 interface (PC)
CAN interface
(1)
+15 V auxiliary (Protected)
Digital inputs
Digital outputs
Analog outputs
Analog reference
PTC inputs
Not used
Signal
5 V Incremental encoder
power supply
Incremental encoder interface
Incremental encoder reference
+15 V aux (Protected) /
Encoder Supply
Digital outputs
Analog input # 1
Analog input # 2
Positive analog reference
Negative analog reference
Drive of the main contactor
Electronics power supply
Main contactor feedback
Digital inputs
Relay digital output (NC)
Relay digital output (NO)
Relay digital output (COM)
Return
Advance
BASIC CONNECTION FOR FIRST POWER-UP
WEG motors used with the CVW300 are supplied with a speed sensor
(encoder), and it must be connected to the CVW300 for the reading
of the signals according to
Table 7 on page
Table 7: Encoder wiring diagram
Encoder Wires
Red
Yellow
Green
Blue
Black
NOTE!
In order to connect the encoder to the CVW300, you
must additionally short XC10 pins 3, 5 and 7, together
with XC10 pin 8. The WEG´s encoder supply is done by
the +15 V aux power supply, in XC10 connector, pin 9.
When present, the HMI Interface must be connected to the CVW300
by means of a shielded cable with a female DB9 terminal, according
to
Table 8 on page
9.
Table 8: HMI wiring diagram
Female DB9 Connector
1
2
3
4
5
6
7
8
9
In order to purchase a HMI accessory, refer to the user manual.
Most electric drive applications need an accelerator. It is
recommended to use electronic accelerators with potentiometer
with minimum impedance of 5 kΩ and with the wiring suggested in
Figure 6 on page
9.
Figure 6: Accelerator wiring
In case the contactor used between the CVW300 and the battery
has an auxiliary contact, its wiring must be done according to
7 on page
9.
Figure 7: Contactor wiring
9.
CVW300
XC10 pin 9
XC10 pin 2
XC10 pin 4
XC10 pin 6
XC10 pin 8
CVW300
-
XC9 pin 1
XC9 pin 1
XC9 pin 4
XC9 pin 3
XC9 pin 4
XC9 pin 2
XC9 pin 2
-
XC10 Pin 14
XC10 Pin 12
XC10 Pin 8
Figure
CVW300 | 9