ALIGNMENT AND ADJUSTMENTS
To avoid risk of electrical shock, personal injury or death; disconnect power to washer
before servicing, unless testing requires power.
Service Mode
Service Mode:
1. The washer must be on to go into the Service Mode.
2. The motor speed will be displayed when started (It displays 0 when the motor does not spin).
3. The present state of the machine will not be changed.
(i.e., the current cycle in progress will not be interrupted and only the display will change)
4. To exit Service Mode, press Delay Start and Pre Soak Keys for 3 second again, or Power Key.If
no key is operated during Service Mode for 5 minutes, the machine will return to normal user
mode.
Quick Spin Test Mode
Definition of Quick Spin Test Mode:
- Quick Spin Test Mode is to do Spin Check. (High RPM)
How to Enter:
- During Service Mode, press the Delay Start and Softener Option Keys for 3 seconds to enter
Quick Spin Test Mode.
- Cannot enter once the washing cycle has started.
Quick Spin Test Mode:
As it enters into the Quick Spin Test Mode, it starts spinning and reaches to its maximum RPM.
Once the Spin speed reaches the maximum RPM, the speed drops immediately.
To hold Quick Spin Test Mode (entering Hold Speed Mode), press the Start/Pause button. If the
Start/Pause button is pressed during Quick Spin Test Mode, it will stop accelerating and hold its
spinning speed for 10 minutes before going back to Quick Spin Test Mode.
Also, to cancel the hold and allow Quick Spin Test Mode to continue, press the Delay Start and
Softener Option Keys together for 3 seconds.
If you hold down the Delay Start and Softener Option keys for three (3) seconds when the washing
machine is not in Hold Speed Mode, Quick Spin Mode is exited and Service Mode is restored.
F900A WASH_WA50F_ MANUAL_DC68-03132C_EN(需要翻译的文件).indd 7
WARNING
Delay Start and Pre Soak
Delay Start + Softener Option
Delay Start + Softener Option
3 sec
While it is not in Hold Speed Mode
While a cycle is not running
7
Delay Start + Softener Option for 3 sec or
after 10 minutes