Abicor Binzel ABIDRIVE V2 Instructivo De Servicio página 49

Ocultar thumbs Ver también para ABIDRIVE V2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TIG cold-wire feeder
The applicable parameter settings can be found in the following table:
Function
Description
dt
Wire feed delay time
rE
Wire retraction time
F2
Wire retraction feed rate
F6
Power source shut down with
2 and 4-cycle
T2
Rocker
T4
Rocker
Tab. 15
Settings for 2-cycle and 4-cycle mode
Move the rocker towards T4 to switch on the wire feed and the welding current source. Move the rocker again to switch off
the welding current source.
The wire feeder stops in the 3rd or 4th cycle, enhancing the quality of the current welding process (wire stops sooner) and
preventing the wire from sticking in the weld pool.
The setting is made using function F6. Here, the wire feed starts when the rocker is moved towards T2 and stops when it is
released.
4T
Normal
(F6=4)
Normal
(F6=3)
Interval
(F6=3)
Fig. 12
Example of 4-cycle mode
BAL.0415.0 • 2018-10-22
Explanation of the setting process
 Tab. 9 Display indicators after switching on on page EN-11
 Tab. 9 Display indicators after switching on on page EN-11
 Tab. 10 Display indicators for advanced functions on page EN-13
 Tab. 10 Display indicators for advanced functions on page EN-13
Switch the wire feed on or off
Switch the welding current source on or off
t1
t2
t3
t4
m/min
dt
rE
m/min
dt
rE
ton
m/min
dt
tof
rE
6 Putting into operation
T2
Motor
Motor
Motor
EN - 17

Publicidad

Tabla de contenido
loading

Tabla de contenido