use the UP and DOWN keys to move on to another
parameter: the whole display will flash fast to tell
you the setting has been saved.
NOTE: the parameters' numerical value can only
be edited with the + and - keys with the motors
stopped, while you can view the parameters at any
time.
The sequence of parameters in easy setup mode is
given in the table below.
WARNING! Certain parametri (
are particularly critical and editing them once the
system is already up and running could result in
PARAMETER
AND DEFAULT
FUNCTION
SETTING
0- 02
Number of motors
Auto-closing after
1- 00
pause time
Auto-closing pause
2- 30
time
Closing after power
3- 00
cut
Closing
4- 05
time lag M1
5- 00
Pre-flashing
Step-by-step
6- 00
mode
Flashing light
7- 00
setup
8- 00
Limit switch enabling
Torque level during
9- 06
normal travel
A- 00
Opening jolt
b- 00
Encoder setup
0-
8-
b-
,
and
)
VALUE
ON
DISPLAY
1 motor
01
2 motors
02
disabled
00
01 - 15 number of closing attempts (stopped by photocell) before
gate is left open permanently
always tries to close, with no limit on number of attempts
99
00 - 90 pause in seconds
92 - 99 2 minutes...9 minutes pause time
disables closing when power is resumed
00
enables closing when power is resumed
01
disabled
00
01 - 60 time lag in seconds
disabled
00
01 - 10 pre-flashing time in seconds
5 second pre-flashing time before closing only
99
opens stops closes stops opens stops closes...
00
apartment block, restarts the pause timer
01
apartment block, closes from fully open
02
opens closes opens closes
03
opens closes stops opens
04
steadily lit (flashing light responsible for flashing)
00
slow flashing switched on
01
slow flashing switched on while opening; fast flashing while closing
02
no limit switch connected to control unit
00
open and closed limit switches connected to control unit
01
only open limit switches connected to control unit
02
01 - 08 1 minimum torque... 8 maximum torque
disabled
00
01 - 04 time in seconds
neither present
00
both optical (8 pulses/revolution)
01
both magnetic (1 pulse/revolution)
02
malfunctioning; to put the edited parameter setting
into effect, you will need to disconnect the power,
restart the system and repeat travel programming.
6.2.2
Restoring factory settings
NB: this procedure is only possible provided no
password has been entered to protect the data.
Disconnect the control unit's power, hold down the
UP and DOWN keys together, then power up the
unit again while keeping the keys pressed down:
after 4 seconds, the message
the display, telling you that the values have been
reset.
DESCRIPTION
rES-
will flash on
29