Brake At End Of Cycle; Brake When Photocell Beam Is Broken; Brake On Stop Command; Brake On Reversing (Op-Cl Or Cl-Op) - Roger H70/200AC Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
60 00

Brake at end of cycle

00
OFF (brake disabled at end of cycle)
01
ON (brake at end of cycle)
61 00

Brake when photocell beam is broken

00
OFF (brake disabled when photocell beam is broken)
01
ON (brake when photocell beam is broken)
62 00

Brake on STOP command

00
OFF (brake disabled when STOP command is given)
01
ON (brake when STOP command is received)
63 00

Brake on reversing (OP-CL or CL-OP)

00
OFF (brake disabled before movement reversed)
01
ON (brake before movement reversed)
64 05

Braking time

01
20
TENTHS OF A SECOND
-
Be careful when you edit this setting: choose a low value to stop the gate starting to move again instead of
braking.
65 08

Force applied by brake

01
08
1 minimum force... 08 maximum force
-
70 02

Number of motors

01
1 motor
02
2 motors
0-
NOTE: parameter
72 00

Limit switch enabling

00
no limit switch connected to control unit
01
open and closed limit switches connected to control unit
02
only open limit switch connected to control unit
8-
NOTE: parameter
73 03

Safety edge 1 setup

00
NOT PRESENT
01
SWITCH, reverses while opening only
02
8k2, reverses while opening only
03
SWITCH, always reverses
04
8k2, always reverses
40
in easy setup mode.
in easy setup mode

Publicidad

Tabla de contenido
loading

Productos relacionados para Roger H70/200AC

Tabla de contenido