DIP Switch Settings

ON
1 2
3
4 5 6
7 8
DIP 1: LEDs operation
On: LEDs enabled
Off: LEDs disabled
DIP 2-3: PIR Detection Sensitivity
Sensitivity
Low
Mid
Normal
Maximum
DIP 4: Auxiliary relay control
ON: Enabled
OFF: Disabled

Walk test

Two minutes after applying power, walk test the protected area to verify
proper operation.
For installations on uneven surfaces slide the PCB inside the internal base to
the appropriate setting according to the desired height (1.0m, 1.5m, 2.2m,
2.7m) as printed on the bottom left corner of the PCB or use the standard
swivel accessory.
For reducing the detection range, slide the PCB up or tilt the swivel down.

LEDs Display

LED
State
YELLOW
Steady
Steady
GREEN
Steady
RED
Steady
Flashing
All LEDs
Flashing
(One after
another)
:
Notes
1. DIP-Switch 1 should be in ON position to enable LED indications.
2. Only one LED is active at any one time. For example, in the case of both PIR channels detection, either the
steady yellow LED or the steady green LED is displayed (the first to detect), followed by the alarm red LED.

Relay Mode / Bus Mode Jumper

J-BUS jumper (located on the PCB between the red and green LEDs)
is used to define the detector's mode of operation as follows:
8
Factory
Default
DIP2
DIP3
Off
Off
Off
On
On
Off
On
On
Description
Indicates channel 1 PIR detection
Indicates channel 2 PIR detection
Indicates ALARM (Simultaneous 2 PIR channels)
Indicates ALARM (Simultaneous 2 PIR channels)
Indicates malfunctioned communication with ProSYS (BUS mode
only)
Unit initialization on power up
WatchOUT PIR Installation Manual
DIP 5: Used to define the auxiliary relay operation
following an alarm condition, depending on
Day/Night time (defined by 24 Hours / Night
Photocell)
ON (Night): Auxiliary relay is activated only
during nighttime.
OFF (24 Hours): Auxiliary relay is activated
24 hour
DIP 6-7: Defines the time duration that the auxiliary
relay is activated
Activation Time
2.2 seconds
2.0 Minutes
4.0 Minutes
8.0 Minutes
DIP 8: Red LED /3 LED
ON: Red LED only
OFF: 3 LEDs
Switch 6
Switch 7
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Relay
BUS
Mode
Mode
1.00M
1.55M
2.20M
2.70M