Festo Soft Stop SPC11 Serie Referencia Rápida página 22

Ocultar thumbs Ver también para Soft Stop SPC11 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Connect an earth cable with sufficient cross−sectional area
to the drive if the drive is not fitted on an earthed machine
stand. Special earthing measures for components other
than those shown here can be found in the System manual
for the SPC11.
Pin assignment on the Control connection
The function of the input I4 and outputs O4 and O5 can be
configured (see system manual for SPC11). The following
tables describe the factory settings.
Output
O1: P.01
O2: P.02
O3: P.03
O4: P.04
O5: Error
O..: Output
1)
Can be configured; P.04 (factory setting) or Stop
2)
Can be configured; Error (factory setting) or Ready
22
Pin
13
12
11
1)
10
2)
9
Description
Supplies a 1−signal when the
drive is in the appropriate
drive is in the appropriate
position. Supplies a 1 signal for
position. Supplies a 1−signal for
50 ms when the drive moves past
the appropriate position.
the appropriate position
Supplies a 1−signal if there is an
error.
Festo SPC11−... 0404a English

Publicidad

Tabla de contenido
loading

Tabla de contenido