5.6 Electrical connection

Electrical supply must correspond to that indicated on the appliance.
Connection cables have to be sized according to appliance power and installation
requirements.
Please refer to below table:
MUPIR-21-H9
These data are only indication, you must ask an electrician to determine the exact data for
your pool installation.
Use the cable glands and grommets provided inside the heat pump to route cables.
If the length of your cable is more than 10 meters, we advise you to seek advice from
a professional.
A voltage variation of ± 10% during operation is acceptable.
The power supply lines must be securely fastened.
The cable must be suitable for outdoor use.
Model
44
Cable size
2
3x4.0mm
/AWG 12