Installation Location; Care And Maintenance; Service Note - Stiebel Eltron IS 5-1 E Instrucciones De Instalacion Y Uso

Calentador de ducha instantáneo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Operating Instruction
1.6 Important note
All the information in these
Operating and Installation
Instructions must be carefully
followed. These instructions provide
important details regarding the
safety, operation, installation, and
maintenance of the unit.
The outlet must not be
connected to any tab or
fitting other than those specified
1.7 Regulations and Provisions
- Regulations of the local power
supply company should be
observed.
- Regulations of the water supply
company should observed
- Technical data.
- Install the unit flush with the wall.
- Electrical connection to be secure.
The device must be capable
of being isolated from the
mains, for example by fuses, with an
isolating distance of at least 3.5 mm.
in all poles.
If the supply cord is damaged,
it must be replaced by the
manufacturer, its service agent or
similarly qualified persons in order to
avoid a hazard.
The unit must be earthed
(see circuit diagram). To
protect against water penetration,
the cable seal (2) must be used.

1.8 Installation location

The shower unit is to be
installed in a closed, frost-free
room (disconnected units are to be
4
for the user and the qualified installer
stored in a frost-free location, since
there will always be some water left
in the unit) The IS is to be installed
vertically on a wall (hot water
connection downwards).
1.9 First operation
(Only to be carried out by a qualified
installer)
Before switching on, set the
rotary water valve to "Max"
setting until the pipework and the
unit are free of air.
- Check the operation of the water heater.
- Before switching "ON" set the rotary
temperature to "OFF"
Handing over the unit
Explain to the user how the unit works
and familiarise him or her with its use.
- Advise the user about possible
hazards (high water temperature)
- Hand over these instructions, to
be kept in a safe place.

1.10 Care and Maintenance

All that is needed for the housing is a
damp cloth. Do not use any abrasive
cleaning agents or agents containing
solvents.
Maintenance work may only
be carried out by a qualified
installer.

1.11 Service note

When carrying out any work,
isolate the unit from the mains
and shut off the water connection.
- Clean the filter
Disconnect water valve (17), remove
filter (14) and clean. Re-assemble
in reverse order.