Specifications
General Specifications
Dimensions
Jaw dimensions
Maximum measurable
conductor diameter
Mass
Product warranty period
Operating environment
Operating temperature
and humidity
Storage temperature and
humidity
CM4371, CM4372: Approx. 65W × 215H × 35D mm (2.56"W × 8.46"H × 1.38"D)
CM4373, CM4374: Approx. 65W × 250H × 35D mm (2.56"W × 9.84"H × 1.38"D)
(excluding protruding parts, operation grip, and jaw)
CM4371, CM4372: Approx. 69W × 14D mm (2.72"W × 0.55"D)
CM4373, CM4374: Approx. 92W × 18D mm (3.62"W × 0.71"D)
CM4371, CM4372: φ33 mm
CM4373, CM4374: φ55 mm
CM4371, CM4372: Approx. 340 g (12.0 oz.) (excluding batteries)
CM4373, CM4374: Approx. 530 g (18.7 oz.) (excluding batteries)
3 years
(Measurement accuracy is defined in terms of a 1-year accuracy and a 3-year
accuracy.) (3 years: reference values)
Number of jaw open/close cycles: 30,000
Indoors, pollution degree 2, altitude up to 2000 m (6562 ft.)
-25°C to 65°C (-13°F to 149°F), 90% RH or less (no condensation)
-30°C to 70°C (-22°F to 158°F), 90% RH or less (no condensation)
Specifications
39