enGliSH
function
capacitance
Maximum input: 600V AC RMS or 600V DC
temperature
frequency
Duty cycle
Sensitivity: 250mV and < 20V RMS
Maximum input: 600V AC or 600V DC RMS
otHer MeaSureMent applicationS
Maximum input: 600V DC or 600V AC RMS
• Diode test: Approx. 1mA, open circuit voltage ~3.0V DC
• continuity check: Audible signal <10Ω, max current 1.5mA
• Sampling frequency: 3 samples per second
• auto power off: After ~15 minutes of inactivity.
• overload: "OL" indicated on display
• polarity: "-" on display indicates negative polarity
• Display: 3-3/4 digit, 4000 Count LCD
4
electrical SpecificationS
range
40.00nF
400.0nF
4.000μF
40.00μF
400.0μF
4.000mF
-40° to 1832°F
-40° to 1000°C
10Hz to
1MHz
0.1% to 99.9%
(≤100kHz)
resolution
0.010nF
0.100nF
0.001μF
0.010μF
0.100μF
0.001mF
≤0°F ±(2.8% + 12 digits)
1°F
1°C
0.001Hz
to 1kHz
0.01%
(Range: 10% – 90%)
accuracy
±(4% + 25 digits)
±(4% + 8 digits)
±(10% + 9 digits)
>0°F ±(2.8% + 6 digits)
±(2.8% + 6 digits)
±(0.1% + 5 digits)
±1.5%