Descargar Imprimir esta página

How To Mount; Wiring Connection; Conduit Connection - Friedrich MD12Y3JM Manual De Instrucciones

Publicidad

Idiomas disponibles

Idiomas disponibles

How to mount

• Select and mark the position for fixing
bolts.
• Drill the hole for set anchor on the face of
ceiling.
CAUTION : Tighten the nut and bolt to prevent unit falling.

Wiring Connection

Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.

Conduit connection

1. Remove the bushing rubber product attached on the indoor unit.
2. Set the connecting cable into the terminal block of indoor unit, and tighten set screw to lock the
conduit bracket to the indoor unit.
3. Join the conduit and the conduit bracket together.
• Insert the set anchor and washer onto the
• Mount the suspension bolts to the set
• Secure the installation plates onto the
Old building
Terminal Block of Indoor Unit
1(L1) 2(L2)
3
Connected to outdooor unit
Lock nut
Conduit
suspension bolts for locking the
suspension bolts on the ceiling.
anchor firmly.
suspension bolts (adjust level roughly)
using nuts, washers and spring washers.
1 Set anchor
2 Plate washer
3 Spring washer
4 Nut
5 Suspension
bolts
Conduit
mounting
plate
Installation Manual 19
Installation
New building

Publicidad

loading

Este manual también es adecuado para:

Md18y3jm