LMRC-112 with Class 1 Dimming
Corner Mount
Ceiling Mount
Sensor
Sensor
Scene Switch
LMRC-111 with Class 1 Dimming
Line
Voltage
Line/Hot
Black wire
Neutral
White wire
Room
Controller
Deep J-Box
Red wire to Load
0-10V Gray and Violet wires to Load
WARNING: TURN THE
POWER OFF AT THE
CIRCUIT BREAKER
BEFORE WIRING.
PLUG N' GO OPERATION (PNG)
Plug n' Go supports the most energy efficient control strategy. For
example, if at least two loads, one switch and one occupancy sensor
are connected to the DLM local network, the system operates load A as
Automatic ON, Automatic OFF and load B as Manual-On, Automatic-Off.
See DLM device Quick Start Guides to determine how each device
affects the PNG operation of the LMRC-111/112.
Load Control Arbitration
To take full advantage of automatic PnG configuration, review these
simple rules about load control arbitration.
After the room controllers are connected to the DLM Local Network and
powered up they automatically negotiate to determine which controller
becomes the Master and which load numbers are assigned to each
relay on the DLM Local Network.
The Master is the controller with the most load relays and the highest
serial number.
Example: In a DLM local network
with only LMRC-112 room
controllers, the LMRC-112 with the
highest serial number is the Master,
carrying Load 1. The next highest
serial number would have Load 2,
and so forth.
Line
DLM Local Network
Voltage
Low Voltage
LMRJ Cables
Room
Controller
Deep J-Box
Yellow wire to Load B
Red wire to Load A
0-10V striped wires to Load B
(Gray/Yellow and Violet/Yellow)
LMRC-111 with Class 2 Dimming
Room
Load
Controller
Switched with
0-10 Volt control
Dimming Ballast
LED Driver, etc.
Deep J-Box
Red wire to Load
0-10V Class 2 Dimming control wires
Load A ON/OFF/Dim button
Load B
Load A
LMRC-112
Only
O-10V Violet and Gray wires for Load A
(Not Used for a Switched Load)
Load
Line/Hot
Examples
Black wire
(any relay)
Neutral
Switched
White wire
A
etc.
Switched with
0-10 Volt control
B
B
Dimming Ballast
LED Driver, etc.
Line
Voltage
Line/Hot
Black wire
Neutral
White wire
Load
Switched with
0-10 Volt control
Dimming Ballast
LED Driver, etc.
0-10V Class 1 Gray and Violet wires
(not used)
Daylighting
Sensor
Blue LED ON when load
is ON.
Load button:
Press & release for ON/
OFF.
Press & hold to Dim.
2
LMRC-112 with Class 2 Dimming
O-10V Gray and Violet wires for Load A
Line
(Not Used for a Switched Load)
Voltage
Line/Hot
Black wire
Neutral
White wire
Room
Controller
Deep J-Box
Yellow wire to Load B
Red wire to Load A
0-10V Class 1 striped wires (not used)
0-10V Class 2 Dimming control wires (available for each load)
0-10V Class 2 Connections
Tie-Down for
0-10V & LMRJ
cables
Load B
(LMRC-112 Only)
PLACEMENT EXAMPLE
Corner Mount
Occupancy
Sensor
LMRC-11x
Room Controller
J Box
Ceiling Mount
Occupancy
To
Sensor
Load
Class 2 to 0-10V
Dimming Ballast
Serial
Room
Number
Controller
LMRC-112
0461373638
LMRC-112
Master
0461373679
Load
Examples
(any relay)
Switched
A
etc.
Switched with
0-10 Volt control
B
B
Dimming Ballast
LED Driver, etc.
Load A
Gray (-)
Violet (+)
DLM Local Network
(low voltage, Class 2)
LMRJ cables
Switch/
Dimmer
Load
Control
3
A
0341373638
4
B
1
A
0341373638
2
B