Setting Force Controls and Final Adjustment of
Limit Switches (continued)
The garage door opens rapidly, and can cause serious
injury or death.
Keep the path clear.
Position the ladder to the side of the Power Head so it is
clear of all moving parts of the Opener and the door.
Set the door Opener to use the minimum force needed
to open the door.
B
OPEN ADJUSTMENT
On front panel of Power Head find adjusting screw
marked "OPEN" (Figure 9).
Gently turn screw counterclockwise until it stops.
Very little force is required to turn adjusting screw.
Press Wall Console to open garage door.
Observe if door stops at "OPEN" limit switch.
If door is fully open—adjustment is finished.
If door stops but is not fully open,
a.
Measure distance between bottom of door
and top of door opening.
b.
Move "OPEN" Limit Switch that same distance
toward Power Head.
If door stops before reaching the
"OPEN" Limit Switch
a.
Slightly increase OPEN Force setting (clockwise).
If door fails to move, see Troubleshooting Section,
pages 15 & 16.
C
Run Door Opener
Cycle opener a few times to double check settings.
Repeat adjustment steps as necessary.
C
H
2:
A
DJUSTMENT
Limit Switch and Force Adjustments must be completed
before checking the contact reverse function (Figure 10).
A
Open garage door using Wall Console.
B
Lay a 2" x 4" board flat in center of doorway.
C
Close door using Wall Console.
D
Check that door stops and reverses within 2 seconds after it
contacts board:
If door does not reverse, decrease Close Force until
door reverses.
If door still does not reverse, move Limit Switch
toward door.
E
Check Safe-T-Beam® System operation:
If beam is blocked, door will not close.
10
WARNING
S
C
ETTING
ONTACT
R
F
EVERSE
UNCTION
NOTE
6
LIMIT
SET
OPEN
FORCE
MORE
CLOSE
FORCE
FORCE
RADIO
SIGNAL
LEARN
CODE
Figure 9 Locate controls
The door must contact the 2" x 4" board before the
Carriage activates the Close Limit Switch. If not,
readjust the Close Limit Switch.
Figure 10 Checking Contact Reverse
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
NOTE
2" x 4" board
laid flat
NEC
CLASS 2
PUSH
1
BUTTON
2
COM
SAFETY
3
BEAM
4
DO NOT
PUSH
5
LIMIT SET
UNLESS
DOOR IS
ATTACHED
6
LIMIT
SET
OPEN
FORCE
MORE
CLOSE
FORCE
FORCE