C
Check Step 5:
HECK
M
Check ceiling or space above where Opener Power Head will be
mounted (Figure 5):
A
Measure from garage door center line mark toward rear
of garage:
•
Approximately 10' back if garage has a 7' 6" door.
•
Approximately 11' back if garage has an 8' 0" door.
B
Find location of ceiling joist or truss above where Opener
Power Head will be and estimate type and quantity of
materials needed for your installation (Figure 6).
MOUNTING EXAMPLES
Perforated Angle Iron
Figure 6 Mounting methods for open beam or finished ceilings
C
Check Step 6:
HECK
P
OWER
A
Check that there is a 15 Amp 120 Volt grounded electrical
outlet or grounded permanent wiring box (per building code)
within 3' of Opener Power Head:
•
If not, an outlet or wiring box must be installed. Contact
a licensed electrician for installation.
•
If building codes require permanent wiring, Power Head
must be partially disassembled to install appropriate
wiring in place of Power Cord. See page 19
Permanent wiring must be installed by a Licensed
Electrician. Not all Genie Factory Authorized Dealers are
Licensed Electrician's. Contact someone who is a Licensed
Electrician.
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
P
H
OWER
EAD
A
OUNTING
REA
Conduit
C
G
EILING FOR
ROUNDED
S
OURCE
NOTE
FOR 7-1/2' DOORS
Wood
Figure 5 Check Power Head location
Perforated Straps
CHECK FOR 15 AMP, 120 VOLT GROUNDED OUTLET OR
WIRING BOX WITHIN 3 FEET OF THE POWER HEAD.
10'
11'
FOR 8' DOORS
FINISHED CEILINGS
Locate ceiling joists or trusses
using a stud finder or similar
device.
Attach angle iron (not included)
to joists or trusses through
finish material using Lag Screws.
OPEN CEILINGS
Straps and angle iron may attach
directly to joists or trusses.
7