Installation

5
Connection points
1. Compressed air feed 4 l/s, 4 bar (for use with au-
tomatic fi lter cleaning).
2. Electric feed (for use with integrated control box).
3. Connection point for micro switch circuit(where
existing).
4. Connection of motor tension from a separate con-
trol box (in some cases).
5. Inlet to cyclone (can be rotated for preferred direc-
tion).
6. Exhaust.
2014-10-22
1
6
7
7. Holes for fi tting the unit to the ground (where
existing).
Th e unit can be mounted on concrete surface/fl oor of
2
suitable thickness.
3
Th e electrical connection should be connected to
adequate starting equipment. A certifi ed electrician
should make the installation. 5 pin Euro connection
is available as an alternative.
Th e equipment is prepared to draw 3-phase electric
feed and low volt cabling into its enclosure.
4
Electric cables should be mounted to make it possible
to raise the unit 200 mm for potential bearing changes;
without that the electrical connection would need to
be disconnected.
A separate, lockable disconnect must be installed where
it is readily accessible to the pump. Connect the pipe
work to the inlet and possible to the outlet. Never
start the pump without the correct cables and hoses
being connected. If the outlet is directed up it should
be connected with an exhaust diff user, a bend or a fl ap
so rainwater and objects do not fall into the outlet.
Exhaust air can be between 100-150 o C.
Put the plastic bag under the cyclone or connect the
container.
DC 11-Module - 38
Part No 94153-D