Descargar Imprimir esta página

Connections To Various Main Power Supplies; Trasformation To Operate With Other Gas Type; Cooktop; Oven - Diamond G77/6BFA11-N Manual Del Usuario

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.5

CONNECTIONS TO VARIOUS MAIN POWER SUPPLIES

1N AC 220...240 V 50/60 Hz
elements 240V
4.
4.1

COOKTOP

- Remove the grills, the flame-spreader and the burning assembly
- Remove the knobs
- Remove the front panel.
REPLACING THE WORKTOP BURNER NOZZLE
Using a size-12 spanner, replace the burner nozzle (Fig.2 position 2) with one corresponding to the type of gas selected,
following Table II Injectors
REPLACING THE WORKTOP PILOT BURNER NOZZLE
- Remove the two blocking dies (Fig.3 position 4) with a 4mm Allen-key.
- Lift the pilot burner's head (Fig.3 position 5).
- Using a size-5 spanner, replace the nozzle (Fig.3 position 4) of the pilot burner with one corresponding to the type of gas
selected and following Table II Injectors
- Before installing the head (Fig. 3 position 5), adjust the primary air by turning its regulator (Fig. 3 position 6). Ignite the
pilot and check the flame's length and quality, which should not be too weak nor too thin, but approx. 20mm long, almost
detached from the head and without a yellow tip (L.P.G. gas).
4.2

OVEN

REPLACING THE OVEN BURNER NOZZLE
After removing the oven bottom, disassemble the protection box. Using a size-12 spanner (Fig. 4 position 4), replace the
burner nozzle with one corresponding to the type of gas chosen and following Table II Injectors.
REPLACING THE PILOT BURNER NOZZLE
N.B.: We advise to first remove the spark plug because it can easily break.
ADJUSTING THE OVEN BURNER
Replace the idle screw (Fig. 5 position 11) located on the thermostat with one corresponding to the type of gas chosen,
following Table II Injectors. Screw the idle bypass screw fully down.
The primary air is adjusted by setting the primary air regulator (Fig. 4 position 8) in accordance with Table II Injectors
After adjusting the distance, fix it with the screw; re-assemble the protection after having mounted the pressure intake screw.
GB
MODEL
VOLTAGE TYPE
1N AC 220...240 V 50/60 Hz
electrical diagram drawing n°
TRANSFORMATION TO OPERATE WITH OTHER GAS TYPE
G77/4BFE7
Max.
n° cables
A/f
18,3
1081
PE (earth)
N
(NP)
L
(R)
1
- 20 -
mm
2
3 x 2,5
yellow-green
blue
brown

Publicidad

loading

Este manual también es adecuado para: