Installer system test

TUE
70
Inside
During installer setup, press t
repeatedly until "Test" appears
0120
DONE

System test System status

1
Cooling
system
2
Fan system
3
Heating
system
4
Emergency
heating
system
5
Humidifier
6
Dehumidifier 0 Off
7
Ventilator
How to Use the Installer System Test
The Installer Test is part of the Installer Setup Menu.
1. Enter the Installer System Test by entering
Installer Setup.
2. The test appears at the end of the Installer
Setup Numbers.
20
Press DONE to terminate testing
0 Off
1 Test cooling stage 1
2 Test cooling stages 1 & 2
0 Fan off
1 Fan on
0 Off
1 Test heating stage 1
2 Test heating stages 1, 2
3 Test heating stages 1, 2, 3
4 Test heating stages 1, 2, 3, 4
0 Off
1 Test EmHeat stage 1
2 Test EmHeat stages 1, 2
0 Off
1 On
1 On
0 Off
1 On
Test
number
DONE
Press s t to
select test

Other messages

P
Ventilation meets ASHRAE 62.2
standard (Function 0404)
F
Ventilation does not meet ASHRAE
62.2 standard (Function 0404)
Err
See error codes
CAUTION: EQUIPMENT
DAMAGE HAZARD. Compressor
protection is bypassed during
testing. To prevent equipment
damage, avoid cycling the com-
pressor quickly.
3. See above for available Installer System
Tests.
4. If installed with a Discharge Air
Temperature Sensor (ISU365=1), press
MORE to view the discharge temperature,
and press CANCEL to return to the Installer
test screen.

VisionPRO® IAQ
System
status
1
TEST
Press s t to
change status
69-1816EFS—03
0

Publicidad

Tabla de contenido
loading

Tabla de contenido