EnviroBoss EB130 Manual Del Propietário página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CONTROLS AND OPERATING
INSTRUCTIONS
Set unit upright
NOTICE: Transporting or storing the unit in a
horizontal position is not recommended. When the
machine is placed in a horizontal position, the oil
from the compressor can flow into the
refrigerant coils and reduce the ability
of the dehumidifier to function and
possibly damage the unit. If the unit
has been placed in a horizontal
position, set it upright and let it stand
for at least 30 minutes before turning it
on.
Positioning a Dehumidifier
For best results, operate your
dehumidifiers in an enclosed area. Close
all doors and windows to maximize water
removal efficiency. Place your
dehumidifier away from obstructions, and
keep it away from anything that could
block airflow into and out of the unit. For
more information about creating an
optimum humidity control environment,
contact EnviroBoss at 800-932-3030.
Extend handle
Release the handle by rotating red locking
lever outward, then lift handle up into
place. Rotate red lever back into locked
position to secure handle in operating
position.
NOTICE: Do not use the extended handle
to lift the unit off the ground horizontally.
Do not use the extended handle as an
attachment point to strap the unit in a
vehicle for transport. These uses will
place undue strain on the handle
attachment points in the housing.
Set up drain hose
The EB130 condensate pump connects to
a plastic drainage hose. This hose is
equipped with a quick-connect fitting for
quick attachment to the provided drain
hose. Unwrap the entire hose and place
the unattached end in a sink, drain or
bucket – anywhere that water can drain
out or be collected safely. If you use a
bucket or other container for water
collection, check it regularly to prevent
overflows.
NOTICE: Uncoil and straighten the entire
drain hose. Do not leave any part of the
hose coiled on the unit and do not place
07-02333B EB130
the end of the hose higher than 20 ft. (6 m) above the
bottom of the unit. Also check for kinks or other
obstructions that might restrict the flow of water. A kink
or blockage will cause the unit to turn off produce an
ER9 error code. See "Error Messages" below for more
information.
FIG A: PARTS IDENTIFICATION
FRONT
Power cord and
drain hose
storage.
Humid air inlet.
Air filter.
Front panel. Remove to
access the pump and
coils for cleaning. See
Fig. B.
REAR
Integrated handle. Use the
red lever to lock handle
upright for use or down
for loading or storage.
Control panel.
Power cord
socket.
Drain hose quick-
connect.
Model serial
number label
Process (dehumidified)
air outlet.
2
EnviroBoss

Publicidad

Tabla de contenido
loading

Tabla de contenido