Plug In Electrical Cord; Turn The Unit On; Control Panel Guide - EnviroBoss EB130 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Plug in electrical cord

The dehumidifier should be plugged into a GFCI-
protected 115 volt outlet rated for at least 15 amps.
Remove the cord from the storage tray and uncoil it.
Always plug the cord firmly into the unit first, and then
plug the other end into a suitable electrical outlet.
Startup display and normal display modes
When unit is first plugged into AC power, the control
panel display will briefly cycle through a series of
readouts. This is part of the unit's self-diagnosis
procedure and no user intervention is required.

Turn the unit on

The control panel has a display and a touchpad with four
keys. Press the ON/OFF to turn the unit on. The unit will
now go through a compressor delay countdown (up to
60 seconds in duration) and a self-diagnostics process,
then switch to normal display mode.
CONTROL PANEL
DISPLAY
ON/OFF
ON/OFF
DISPLAY MENU
MENU SELECTION /
UP KEY
PURGE PUMP
UNIT ON 00 HRS
INLET 00°C / INLET 00%
The first line of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see "Job Hours Reset"
below). The second line of the display alternates
between inlet temperature and inlet humidity.
User Settings Menu
A number of settings may be changed by the user.
System information can also be displayed. These items
are accessed by pressing DISPLAY MENU. Each press
of the key will display the next parameter. When you
07-02333B EB130
PURGE PUMP
DISPLAY
MENU
MENU
SELECTION /
UP KEY
Press and release to turn unit on
or off.
Press to select next item in menu.
Menu item will show in display.
Press to toggle or select values in
menu displayed.
Press and release to start purge.
Display will count down seconds
remaining until purge is complete.
reach the parameter you wish to adjust, press MENU
SELECTION to increase the value. Press DISPLAY
MENU again to accept the setting and re-start the
display cycle.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
Error messages
If the onboard diagnostics discover a problem, the unit
will display an error message. See "Error Messages,"
below, for an explanation of each message.

Control Panel Guide

ON/OFF. Press to turn the unit on or off. When the
machine is turned on, the display normally reads
PLEASE WAIT COMP. DELAY and performs a numeral
countdown from a maximum of 60 seconds to 0. This
delay allows time for refrigerant pressures to equalize for
easier starting. Once the unit completes the compressor
delay, the display shows UNIT ON XX HRS and cycles
between INLET XX°F and INLET XX%. NOTE: If no
compressor delay countdown is displayed, a delay is not
necessary and the machine will begin operation
immediately.
DISPLAY MENU. Press to cycle through the display of
additional dehumidifier conditions and User Settings. To
return to the main menu, press the ON/OFF key once.
MENU SELECTION. Press to change the values of the
"User Defined" settings. The MENU SELECTION key
acts as the UP key for adjusting the setpoint for
Humidistat mode operation. See User Settings Menu
(next page) for details.
PURGE. Press to empty water from the condensate
pump reservoir. The display will read PUMP PURGING
with a numeral countdown.
NOTE: During normal operation, the pump purges auto-
matically.
3
EnviroBoss

Publicidad

Tabla de contenido
loading

Tabla de contenido