Descriptions
HP thermal power yield
Total thermal power
1
Heating time (
)
Heating time in BOOST mode (
2
Heat losses 65°C (
)
1
COP(
)
Electrical data
Power supply
Frequency
Degree of protection
HP maximum absorption
Average absorption
Heating element + HP maximum
absorption
Electric heating element power
Maximum current in HP
Required overload protections
Internal protection
Operating conditions
Min.÷ max temperature heat pump air
intake (90% R.H.)
Min. ÷ max temperature installation
site
Working temperature
HP Maximum settable temperature -
ECO cycle
Maximum settable temperature in an
AUTOMATIC cycle
Compressor
Compressor protection
thermodynamic circuit protection type
Fan
Ejection outlet diameter
Revolutions per minute
Nominal air capacity
Max. pressure head available
Motor protection
Condenser
Coolant
Load
Water storage
Water storage capacity
Max. quantity of hot water that can be
3
used Vmax (
)
Coil for connection to solar thermal
power system
Coil for connection to an auxiliary
heating source
Cathodic protection
Insulation
Defrosting
Transport weight
4
Sound power Lw(A) (
)
Automatic anti-Legionnella
5
disinfection cycle (
)
Maximum working pressure
temperature of incoming air supply 20(max. 15°C), temperature of boiler storage environment 20°C, water heated from 10°C
(1)
to 55°C, (according to UNI EN 16147-2011)
(2)
measurements carried out according to UNI EN 12897-2006
(3)
measurements carried out according to UNI EN 16147-2011
(4)
measurements carried out according to EN 12102-2013
(5)
Automatic activation every 30 days of operation
9S 260 60
kW
kW
h:m
1
)
h:m
W
-
V
Hz
kW
kW
kW
kW
A
A
16A T fuse/ 16A automatic switch, characteristic C (to be expected
Single safety thermostat with manual reset on a resistive element
°C
°C
°C
°C
mm
rpm
3
m
/h
Pa
g
l
l
2
m
0.96 m
2
m
Kg
dB(A)
Bar
EVHP
EVHP
260 60
1.6
1.6
3.1
3.1
9:44
9:44
4:57
4:57
105
105
3.1
3.1
during installation on power supply systems)
Thermal circuit breaker with automatic reset
Safety pressure switch with automatic reset
Centrifugal
Internal thermal circuit breaker with automatic reset
Wrapped externally, not in contact with water
260
260
342
342
2
N/A
N/A
N/A
2 x Mg anode Ø32x260 mm
50 mm rigid PU
Passive with air
110.2
91.5
EVHP
9S 200 60
1.6
3.1
7:16
3:48
76
2.8
1/N/230
50
IPX4
0.50
0.37
2.0
1.5
2.3
4÷43
4÷43
56
70
Rotary
160
1420
350
100
R134a
900
200
276
2
0.96 m
N/A
94
59
YES
7
EVHP
200 60
1.6
3.1
7:16
3:48
76
2.8
200
276
N/A
N/A
90