Maintenance; Maintenance Schedule - Honeywell HW4000 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE

Maintenance Schedule

Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. Perform service and
inspection at intervals shown in Generator Maintenance Schedule (see Table 2).
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poi-
son you cannot see or smell.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
• Shut off engine before performing any maintenance. If
engine must be run, be sure area is well ventilated.
NOTICE
Maintenance, replacement, or repair of the emission
control devices and systems may be performed by any
non-road engine repair establishment or individual.
MAINTENANCE TASK
Check engine oil level
Inspect for/clean debris
Check air filter
Run engine
Clean air filter
Change engine oil
Clean fuel sediment cup
Check/clean spark plug
Clean spark arrestor
Check/adjust valve clearance
Clean fuel tank and strainer
Check fuel line
TABLE 2. Generator Maintenance Schedule
* Perform at every indicated month or operating hour interval, whichever comes first.
** It is recommended that the generator is started every three months to ensure the battery remains charged.
If the unit is stored for more than a year without running, a battery charger may required to recharge the generator battery.
† Clean more often when using generator in dusty areas.
‡ It is recommended that this maintenance task be performed by a service dealer.
HW4000/HW4000L Portable Electrical Generator Owner's Manual
DANGER
Only use OUTSIDE and far
away from windows, doors, and
vents.
Before each
use
X
X
X
Every 2 years (replace if necessary)‡
Accidental starting of generator can cause severe injury or
death. Before performing maintenance, disconnect spark
plug cap from spark plug.
Improper maintenance, or failure to correct a problem before
operation, can cause a malfunction in which you can be seri-
ously hurt or killed. Always follow inspection and mainte-
nance recommendations and schedules in this owner's
manual.
The maintenance schedule applies to normal operating con-
ditions. If you operate generator under severe conditions,
such as sustained high-load or high-temperature, or use it in
unusually wet or dusty conditions, consult your servicing
dealer for recommendations applicable to your individual
needs and use.
FREQUENCY
First month or
Every 3
20 hours of
months or 50
use
hours of use
X**
X
X
WARNING
WARNING
NOTICE
*
Every 6
Every year or
months or 100
200 hours of
hours of use
X
X
X
X
www.honeywellgenerators.com
use
X
X
17

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Hw4000lHw7500eHw7500el

Tabla de contenido