Charging and data connections:
• Charging and wired data connection via USB is only allowed outside the hazardous
areas and only allowed by using the ecom Safety Box SB T01 X1 or the Docking
Station DS T01 X1.
• The Tab-Ex 02 DZ1 may only be charged in a temperature range of -5°C to 45°C.
Power supply requirements:
ATEX/IECEx & Mining
• It must be ensured that the power supply used fulfills all national approvals and
requirements.
• The Tab-Ex 02 DZ1 is suitable up to an input voltage and current of Um = 250V, Im
= 100A. It must be ensured that the electricity supply does not exceed these values.
OPERATING CONDITIONS
• It must be ensured that the device is not taken into zones 0 or 20.
• The specifications of control drawing 45-5485 (ATEX/IECEX), 45-5492 (Mining)
must be observed.
• The device may not be repaired, see Section 7.
5. Ex-Data
5.1 ATEX
ATEX Certificate of Conformity no.:
Ex-Marking:
Ambient temperature:
Approved for zone 1 and 2, device group II, explosion group IIC (explosive gases,
vapors or mist), temperature class T5.
Approved for zone 21 and 22, device group III, explosion group IIIC (combustible
flying, non-conductive dust and conductive dust), maximum Temperature 100°C.
5.3 IECEx
IECEx Certificate of Conformity no.:
Ex-Marking:
Ambient temperature:
Approved for zone 1 and 2, device group II, explosion group IIC (explosive gases,
vapors or mist), temperature class T5.
Approved for zone 21 and 22, device group III, explosion group IIIC (combustible
flying, non-conductive dust and conductive dust), maximum Temperature 100°C.
6
Sira 19ATEX1017X
† II 2G Ex db ia op is IIC T5 Gb
† II 2D Ex tb ia op is IIIC T100°C Db
-20 °C ≤ Ta ≤ +50 °C
IECEx SIR 19.0012X
Ex db ia op is IIC T5 Gb
Ex tb ia op is IIIC T100°C Db
-20 °C ≤ Ta ≤ +50°C