stages. Carefully controlling humidity can increase yields
and reduce the risk of mold or powdery mildew that can
reduce profits.
How the EB60 works
The EB60 refrigerant dehumidifier uses a fan to draw
moist air in and condenses it into water that collects in a
tray and is automatically pumped out through a drain
hose. The unit can be set to operate continuously or the
user may select Humidistat Mode. In Humidistat Mode,
the EB60 will turn on and off automatically to maintain
the inlet humidity level the user has selected.
CONTROLS AND OPERATING INSTRUC-
TIONS
Set unit upright
NOTICE: Always store, transport, and use the unit in
a horizontal position. If the unit is ever placed in a
vertical position, return it to the horizontal position
and let it stand for at least 30 minutes before turning
it on.
Positioning a Dehumidifier
For best results, operate your dehumidifiers in an en-
closed area. Close all doors and windows to maximize
water removal efficiency. Place your dehumidifier away
from obstructions, and keep it away from anything that
could block airflow into and out of the unit. For more in-
formation about creating an optimum humidity control
environment, contact EnviroBoss at 800 932 3030.
Set up drain hose
The EB60 condensate pump connects to a plastic drain-
age hose. This hose is equipped with a quick-connect fit-
ting for quick attachment to the provided drain hose. Un-
wrap the entire hose and place the unattached end in a
sink, drain or bucket – anywhere that water can drain out
or be collected safely. If you use a bucket or other con-
tainer for water collection, check it regularly to prevent
overflows.
NOTICE: Uncoil and straighten the entire drain hose. Do
not leave any part of the hose coiled and do not place
the end of the hose higher than 20 ft. (6 m) above the
bottom of the unit. Also check for kinks or other obstruc-
tions that might restrict the flow of water. Obstructions
may cause a water backup and result in overflows.
Plug in electrical cord
The EB60 should be plugged into a GFCI-protected 115
volt outlet rated for at least 15 amps.
Startup display and normal display modes
When unit is first plugged into AC power, the control
panel display will briefly cycle through a series of
readouts. This is part of the unit's self-diagnosis proce-
dure and no user intervention is required.
07-02330B EB60
Turn the unit on
The control panel has a display and a touchpad with four
keys. Press the ON/OFF to turn the unit on. The unit will
now go through a compressor delay countdown (up to
60 seconds in duration) and a self-diagnostics process,
then switch to normal display mode.
UNIT ON 00 HRS
INLET 00°C / INLET 00%
The first line of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see "Job Hours Reset"
below). The second line of the display alternates be-
tween inlet temperature and inlet humidity.
User Settings Menu
A number of display settings may be changed by the
user. System information can also be displayed. These
items are accessed by pressing DISPLAY MENU. Each
press of the key will display the next parameter. When
you reach the parameter you wish to adjust, press
MENU SELECTION to increase the value. Press DIS-
PLAY MENU again to accept the setting and re-start the
display cycle.
CONTROL PANEL
DISPLAY
ON/OFF
ON/OFF
DISPLAY MENU
MENU SELECTION /
UP KEY
PURGE PUMP
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
All settings and modes are discussed in detail in Control
Panel Guide, below.
Error messages
2
PURGE PUMP
DISPLAY
MENU SELECTION /
UP KEY
MENU
Press and release to turn unit
on
or off.
Press to select next item in
menu. Menu item will show
in display.
Press to toggle or select val-
ues in menu displayed.
Press and release to start
purge. Display will count
down seconds remaining until
purge is complete.
EnviroBoss