16
OPERATION
16
OPERATION
Delay ON/OFF Timer
6
Delay ON - When the air conditioner is off,
set it to automatically turn on from 1 to 24
hours later, at its previous mode and fan
settings.
Delay OFF - When the air conditioner is on,
set it to automatically turn off from 1 to 24
hours later.
NOTE
Each press of the Timer button advances
the timer by 1 hour. After the last press of
the Delay OFF Timer the display returns to
the temperature setting.
Temperature Control
7
To adjust the desired room temperature in
Cool or Dry mode. The desired room
temperature can be set between 60˚F-86˚F
(16 °C–30 °C). Press
increase or decrease temperature setting.
NOTE
Press
and
control panel for 3 seconds, the tempera-
ture display can be switched between
degrees Fahrenheit (ºF) and degrees
Celsius (ºC).
Wi-Fi
8
Enables connection of the air conditioner
to the home Wi-Fi.
To connect Wi-Fi, press the Fan Speed
button on the control panel for 3 seconds.
9
Clean Filter
The Clean Filter LED lights up to notify you
the control panel for 3 seconds to turn off
the Clean Filter light.
NOTE
control panel, not the remote control.
This feature is a reminder to clean the air
filter for more efficient operation. The LED
light turns on after 250 hours of operation.
Clear
10
Cancel Sleep and Timer settings.
NOTE
Press the Clear button on remote controller
for 5 seconds, the Smart Diagnosis function
works.
or
arrows to
button together on the
press Sleep button on
NOTE
Auto Restart: In case of turning off the air
conditioner due to power failure, your unit will
resume its last operation several minutes after
power is restored
Removing Condensation
Buildup
Condensation can build up inside the unit when
the Cool and Dry modes are used. The fan can
be set to run for a short period after the product
is turned off to help keep the inside of the
appliance dry. This option is off by default.
Turning Condensation Fan On
1
Turn on the product, set it to Cool mode
and let it run for at least 10 seconds.
2
Press and hold the [Auto Swing] button for
3 seconds until [On] appears in the display.
3
The condensation fan is now turned on.
When the appliance is turned off, [Co]
appears in the display and the fan will
continue to run for 10 minutes. The
appliance will then shut down as normal.
Turning Condensation Fan Off
1
When the product is powered ON, press
and hold the [Auto Swing] button for 3
seconds until [OF] appears in the display.
2
The condensation fan is now turned off.
The appliance will shut down immediately
when it is turned off.
NOTE
Some functions cannot be used while this option
is turned on.
This option must be set using the control panel,
not the remote control.