• Push " SET " key several times until the " SET " symbol is disappeared to
exit the setting mode.
Real – Time Setting mode
• Push
key to turn on the meter.
• Push "SET" key three times to enter this mode, the " SET " and D-H, m:s
symbol are displayed.
• Push  key three times move to the two flicking digits to day.
• Push "" and "" keys to set the day of the real – date.
• Push "" key move to the two flicking digits to hour.
• Push "" and "" keys to set the hour of the real – time.
• Push "" key move to the two flicking digits to minute.
• Push "" and "" keys to set the minute of the real – time.
• Push "" key move to the two flicking digits to second.
• Push "" and "" keys to set the second of the real – time.
• Push "↵" key to stored these setting.
• Push "SET" key several times until the " SET " symbol is disappeared to
exit the setting mode.
Select a Time Constant mode
• Push "SET" key two times to enter this mode, the "TC" symbol and the
current time constant are displayed.
• Push  and  keys to scroll through the choices and push "↵" key to
store the choice. The choice for the time constant are : 1, 2, 3, 4, 5, 6, 7,
8, 9, 10, 15, 20, 25 and 30 seconds.
• Push "SET" key several times until the " SET " symbol is disappeared to
exit the setting mode.
The time constant is an averaging period. It is used to dampen the
display. If you are experiencing fluctuating flows, a longer time constant
will slow down those fluctuations. The average method is also referred to
as a "moving average".